background image

Rev. 1.2 

 

8. Inputting an External Trigger

 

*Input Signal and Photo coupler 
 

The input signal from the external trigger input connector can be used to control the photo coupler  

inside the Unit to turn the LED Light Units ON and OFF or to control strobe timing.

  

Trigger H/L  
Logic Switch 

Input signal 

Photo coupler 

ON/OFF Mode 

Strobe Mode 

HIGH 
LOW 

OFF 
ON 

Light Units ON 
Light Units OFF 

Lights Units ON for the set time 

No change 

HIGH 
LOW 

OFF 
ON 

Light Units OFF 
Light Units ON 

No change 

Lights Units ON for the set time 

*When operating trigger signal input and communication used External trigger input connector at same time in ON/OFF mode. 

When Trigger logic switch is at H : if either controls setting, Light unit will be turned OFF. 
When Trigger logic switch is at L : if either controls setting, Light unit will be turned ON. 

 

*Connector Layout 

External Trigger Input Connector Plug 

 

 

 

 

 

 

 

 

 

*External Trigger Signal Connection Example 

 

 

 

Signal Specifications 

Rated input voltage 

Maximum input voltage 

ON voltage/ON current 

OFF voltage/OFF current 

ON/OFF response time 

Input impedance 

24 VDC 

26.4 VDC 

14.4 VDC min./3 mA max. 

5 VDC max./1 mA max. 

10 μs max. 

7.5kΩ(per terminal) 

TRIG. IN

1

2

3

10

5

7

9

4

6

8

Exte rn al  Circ u its

VLP- 2 4 3 0 - 4   Con tro l  Un it

1

2

Light Unit ON/OFF

control input

CH1

Light Unit ON/OFF

control input

CH2

COMMON

10

Transistor (NPN)

open collector

Transistor (NPN)

open collector

24 VDC

7.5kΩ

7.5kΩ

22kΩ

22kΩ

3

Light Unit ON/OFF

control input

CH3

Transistor (NPN)

open collector

7.5kΩ

22kΩ

4

Light Unit ON/OFF

control input

CH4

Transistor (NPN)

open collector

7.5kΩ

22kΩ

NO 

Signal 

Cable 

Wire color 

Light Unit ON/OFF 
control input CH1 

Black 

Light Unit ON/OFF 
control input CH2 

Black/White 

Light Unit ON/OFF 
control input CH3 

Brown 

Light Unit ON/OFF 
control input CH4 

BROWN/WHITE 

5 to 9 

No used 

--- 

10 

 

Yellow/Black 

VLC-2430-4 

Summary of Contents for VLC-1230-4

Page 1: ... safety please read this manual thoroughly before starting operation Keep this manual for the whole product lifetime The following warning symbols are used in this manual Be sure to fully understand the contents WARNING A warning denotes a hazard that can cause severe injury or death CAUTION A caution denotes a hazard that can cause injury or damage of equipment ...

Page 2: ...her lighting unit over current may cause a fire or heat CAUTION 1 USE the extension or remote cables 3m maximum to prevent power drop by voltage reduction or malfunction by noise 2 Installation of the product 1 Place horizontally in a well ventilated space on the rubber feet at the bottom of the unit 2 Do not topple or lay on its side 3 Do not put on unstable or vibrational place 4 Do not use in e...

Page 3: ...ectors SMP 02V BC JST 1 output 2 output Insulation resistance 500MΩ min Withstand voltage AC1500V minute External control connectors Trigger input MIL connector MIL C 83503 compliant 10 pole For setting the light intensity and lighting mode e CON 3 pole Intensity Control INT Control manually by volume knobs EXT Remote control by external EIA 232 D Strobe Control NOR The lights are always ON STR St...

Page 4: ...ings for Light Unit connected to output connector CH3 CH4 lit Lit when changing settings for Light Unit connected to output connector CH4 Control Switch Selects internal INT or external EXT control mode Mode Switch Selects normal NOR or strobe STR control mode Trigger H L Logic Switch Selects the logic of the trigger signal External Control Connector For external control with RS 232C communication...

Page 5: ...S 232C or TRIG IN connector on front panel 4 On Off Control It is possible to turn off the light by inputting off signal by External control mode 5 Error Signal Error indicator on front panel will be on if an error of LED lighting unit detected such as breaking of wire Error signal from external signal connector will be output at the same time It does not identify error of CH1 or CH2 or CH3 or CH4...

Page 6: ...s of the ASCII characters from the header to the ID are added the lowest byte is converted to hexadecimal and two characters are sent Example Setting the Light Intensity of Channel 2 to 125 Sent command ID Total Send Data 1 Instruction Data 2 Light Intensity Setting F 000 to 255 000 Min Intensity 255 Max Intensity 000 Lighting Mode Setting S 01 to 10 Refer to Lighting Mode Settings 00 ON OFF Setti...

Page 7: ...01N0300B3CRLF Setting the Lighting Mode Specify the ID and channel and set the lighting mode Setting example Send data Receive data When ON Receive data When NG Setting the lighting mode to Strobe Mode at 200μs for CH2 of the VLC 1230 4 that the ID set to 00 00S0400B8CRLF 00O0050CRLF 00N0300B2CRLF To set ON OFF Signal in ON OFF mode Specify the ID and the channel and set ON OFF signal Setting exam...

Page 8: ... turned ON Connector Layout External Trigger Input Connector Plug External Trigger Signal Connection Example Signal Specifications Rated input voltage Maximum input voltage ON voltage ON current OFF voltage OFF current ON OFF response time Input impedance 24 VDC 26 4 VDC 14 4 VDC min 3 mA max 5 VDC max 1 mA max 10 μs max 7 5kΩ per terminal TRIG IN 1 2 3 10 5 7 9 4 6 8 External Circuits VLP 2430 4 ...

Page 9: ...r OFF according to the external trigger signal input Strobe Mode The Light Units are turned ON for the set time after the external trigger signal input Trigger Input Sequence Diagram A pulse width of ON signal shall be 10μs or more The Light Units will be turned on for at least 40μs even when the input ON signal is less than 40μs If another trigger is input before the Light Units turns OFF in Stro...

Page 10: ...e performance specifications etc by customers after the day of product delivery Faults or damage that occur due to use of the product other than for its designed purpose Faults or damage that occur due to natural or human causes such as saltwater air damage gas damage earthquakes floods fire lighting or armed conflicts Disclaimer VS Technology Thailand Co Ltd shall not be responsible for any appen...

Reviews: