Section 13—The Learn Function
MCP-25/MS
Valco Cincinnati
13-5
Learning Reference Values
The purpose of teaching reference values is so the
system has a baseline value with which to compare
glued versus unglued sections. In order to learn
reference values, the following conditions must be met:
•
D-12, AS-601, or MW-101 sensor(s) must
be used.
•
The sensor(s) must be activated.
To learn reference values, follow these steps:
1. At the “Learn data” screen (Figure 13-12),
press F3 (Refer.). If the conditions listed
above are not met, the screen in Figure 13-13
displays. Press the “OK” button, correct the
condition, and repeat step 1. If the conditions
above have been met, the screen in Figure 13-
14 displays. Go to step 2.
Note!
There are two modes within the refer-
ence-value learn function
—one-time
mode
and
continuous mode
. In order to
run continuous mode, there must be an
unglued section of at least 2 inches
before and after the glue line. Pressing
F2 (Contin.) sets the sensor to continous
mode and ends this learn function
procedure.
2. Press F1 (Onetime) to select one-time mode.
The screen in Figure 13-15 displays.
3. Start the machine
without glue
and run one
box through the system.
4. Press F2 (Yes). The measuring cycle starts
and the “Measuring reference values...please
wait” message displays (Figure 13-16).
Volume
Dist.
Refer.
Pattern
Learn data
F1:
Glue volume
F2:
Distance Sensor <-> ejector
F3:
Reference value
F4
Learn glue pattern
End
F1
F2
F3
F4
F5
Figure 13-12. The Learn data screen
Figure 13-14.
F1
F2
F3
F4
F5
OK
Figure 13-13.
No activated sensor
to learn
a reference value!.
Figure 13-16.
Figure 13-15.
F1
F2
F3
F4
F5
Cancel
For Channel 1,2
you have to learn a reference value
F1: Learn the reference value
ONE TIME from a blank product
F2: Learn the reference value
CONTINUOUSLY with EVERY product
Onetime
Contin.
F1
F2
F3
F4
F5
Cancel
Learn reference value
for channel 1,2
Start machine without glue
and press F2 to start!
Yes
F1
F3
F4
F5
Cancel
Measuring reference
values...
...please wait!
F2
Summary of Contents for MCP-25/MS
Page 1: ...MCP 25 MS Control Manual Number MC051 Release Date June 2004 ...
Page 25: ......
Page 27: ......
Page 28: ......
Page 29: ...3 4 5 1 2 2 4 5 3 1 ...
Page 30: ......
Page 31: ......
Page 33: ...4 8 12 11 10 9 6 7 5 3 2 1 ...
Page 34: ...3 7 9 10 8 5 6 4 1 2 1 4 3 2 ...
Page 35: ...1 3 4 2 ...
Page 36: ...7 9 10 8 3 5 6 4 1 2 ...
Page 37: ...SHD NPN 5 4 3 24V Low Level Detector 0V 1 2 ...
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ...3 4 5 6 2 3 1 5 6 4 1 2 ...
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ...RODUCT 7 10 9 8 3 5 6 4 1 2 8 10 9 2 5 7 6 3 4 1 ...
Page 50: ......
Page 51: ......
Page 52: ...6 8 10 9 7 1 3 5 4 2 ...
Page 53: ......
Page 54: ......
Page 55: ...6 8 10 9 7 1 3 5 4 2 ...
Page 56: ...VA LC O CI NCIN NA TI INC 513 87 4 6550 5 13 87 4 6550 VALC O C INCIN NATI INC ...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 87: ......
Page 99: ...F1 F2 F3 F4 F5 ...