8. Turn the pump off.
9. Reconnect the glue hoses to the applicators.
10. Turn the gear pump back on and activate the applicators to purge
remaining adhesive through the valve(s).
11. Reset the temperature control to the correct setting for the material
you are using.
Warning!
If the system is hot, wear insulated gloves and eye
protection when disconnecting hoses. Failure to observe
could result in personal injury, death, or damage to
equipment.
Occasionally, parts may need to be repaired or replaced. The following
paragraphs contain instructions for removing parts from the hot melt unit.
For drawings and a complete list of part numbers, see Section 10 — Part
Number List.
In the event that a fuse must be replaced, simply remove one of the spare
fuses from the included installation kit and insert the fuse in the appropriate
socket on the 5-zone board (see the following Figure).