MUS01210202
07/01/2020
MELTON, S.L.U. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail: melton@melton.es
35
The channels are identified by the following codes:
t0
Tank
t1
OUTLET 1 hose
t2
OUTLET 1 gun
t3
OUTLET 2 hose
t4
OUTLET 2 gun
t5
OUTLET 3 hose
t6
OUTLET 3 gun
t7
OUTLET 4 hose
t8
OUTLET 4 gun
t9
OUTLET 5 hose
10
OUTLET 5 gun
11
OUTLET 6 hose
12
OUTLET 6 gun
To end the process, press
again.
Programming ENERGY SAVING:
To enter this programme, press
button then
button until
(led is lit).
The two digits on the left show the code of the output to be programmed, which is
selected by pressing the
keys under them. 3 groups can be selected:
b0
Tank
b1
Hoses
b2
Guns
The digits in the centre show the % of the operating temperature that will be used
as the adjustment value for ENERGY SAVING. The
keys under these digits
change the value between 50 and 80%.
Pressing the key, we will save the % of temperature displayed.
To end the process, press
again.
Programming operating parameters:
To enter this programme, press
button then
button until
led is lit.
The two digits on the left show the code of the parameter to be programmed,
which is selected by pressing the
keys under these digits.
The digits in the centre, and also the digits on the right, will show the value of the
parameter. Press the
keys under these digits to alter the values within the ranges
specified in Table 1.
The number of
outputs depends on the
equipment type. 4 is
normal can be 6 with
control card upgrade
.
Summary of Contents for D4-L
Page 2: ......
Page 4: ......
Page 6: ......
Page 95: ...0 1 2 1 1 3 4 53 6 0 53...
Page 97: ...0 1 2 3 4 5 4 0 2 4 6 7 1 1 8 3 7 7 2 02 2 90 1 8 7 2 7...
Page 98: ...0 1 2 103 1 4 5 6 7 3 5 0 8 4 4 9 6 10 7 8 8 8 0 8 8 8 8 8...
Page 99: ...0 1 2 3 4 5 6 5 1 3 5 7 7 2 2 8 4 9 9 9 7 9 7 5 3...
Page 101: ...0 1 2 3 4 5 6 7 87 9 6 7 878 3 9 94...
Page 102: ...0 0 1 2 3 4 5 6 2 3 3 7 4 45...