6. Dismantle the filter, replace the inner mesh and clean all of the other
parts.
7. Clean all of the components well and replace any defective ones.
If using a cleaning agent, make sure it is compatible with the
adhesive being used.Check with the adhesive manufacturer if
you have any doubts.
8. Replace the o-rings.
9. Assemble the complete filter again and carefully insert it inside the hot
manifold casing.
10. Tighten the filter cover with a spanner and close the purging valve.
11. Put the machine at operating speed and bleed the gun circuit.
6.3.4. REPLACING THE PROBE AND RESISTORS
The steps for replacing the resistors and/or temperature probe are described
below.
Before repairing the element, clean the outside to prevent adhesive from getting
into the electric box.
1. Release the screws on the electric box cover.
2. Remove the element to be replaced (probe or resistor).
3. Release the element from the ceramic strip or terminal.
4. Peel the 15 mm wire tips.
5. Connect the element to the ceramic strip or terminal.
6. Insert the replaced part into the hole and close the cover.
7. Re-connect the electricity from the gun to the hose.
Summary of Contents for D4-L
Page 2: ......
Page 4: ......
Page 6: ......
Page 95: ...0 1 2 1 1 3 4 53 6 0 53...
Page 97: ...0 1 2 3 4 5 4 0 2 4 6 7 1 1 8 3 7 7 2 02 2 90 1 8 7 2 7...
Page 98: ...0 1 2 103 1 4 5 6 7 3 5 0 8 4 4 9 6 10 7 8 8 8 0 8 8 8 8 8...
Page 99: ...0 1 2 3 4 5 6 5 1 3 5 7 7 2 2 8 4 9 9 9 7 9 7 5 3...
Page 101: ...0 1 2 3 4 5 6 7 87 9 6 7 878 3 9 94...
Page 102: ...0 0 1 2 3 4 5 6 2 3 3 7 4 45...