1
947753
ISSUE 1
VIP-148L-IC InformaCast® Compliant
IP Talkback Horn
Installation
Mounting (Network Interface)
The VIP Network Extender is designed for wall
or shelf mounting and must be within 300 feet of
the network switch.
Shelf:
Provided with the VIP Network Extender
are four rubber pads. Peel the pads from the
carrier backing and place at the four corners of
the bottom of the unit.
Wall:
Using the hardware provided, secure the
VIP Network Extender to the wall.
Mounting (Horn)
The horn should be mounted 15 to 20 feet
above the floor to allow for best sound
distribution. The unit can be mounted to a wall,
a beam or an electrical box.
NOTE:
For ease of installation, the base can be
attached to the speaker before or after the base
is mounted.
Loosen position adjustment knob
Insert the ball of the base into the socket
of the speaker
Tighten the position adjustment knob
Mount the base to a wall using the two
holes provided. Knockout holes are
provided for punch out should additional
holes be desired.
A “C” clamp is provided with the horn to
allow mounting to a beam. Place the
bolt through the hole in the bottom of the
base to secure the “C” clamp to the
beam. It is suggested that the horn be
mounted to the underside of the “I”
beam to provide maximum positioning
adjustments.
The base has pre-drilled holes for a
double-gang square electrical box, but
by drilling out additional knockout holes,
the base can be mounted to a single-
gang or octagon box
The horn may be rotated or moved up and down
to obtain the desired position by loosening the
position adjustment knob at the bottom of the
unit approximately one turn. Make required
adjustments and re-tighten knob.