Dimensions/Weight

• 9.70”W x 8.60”H x 1.50”D

( 24.64cm x 21.84cm x 3.81)

• 0.194 lbs (.087 kg)

IMPORTANT SAFETY INSTRUCTIONS

For important Secondary Circuit Protection information refer to pages 13-14.

When using your telephone equipment, basic safety precautions should always be followed to reduce 
the risk of fire, electric shock and injury to persons, including the following:

1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol 

cleaners. Use a damp cloth for cleaning.

4. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry 

tub, in a wet basement, or near a swimming pool.

5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious 

damage to the product.

6. Slots and openings in the cabinet and the back or bottom are provided for ventilation, to protect it 

from overheating, these openings must not be blocked or covered. The openings should never be 
blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should 
never be placed near or over a radiator or heat register. This product should not be placed in a 
built-in installation unless proper ventilation is provided.

7. This product should be operated only from the type of power source indicated on the marking label. If 

you are not sure of the type of power supply to your home, consult your dealer or local power 
company.

8.

WARNING:

  RISK OF ELECTRICAL SHOCK, EQUIPMENT MUST BE PROPERLY 

GROUNDED. Your equipment requires a properly grounded three-prong power receptacle for safe 
operation. Have the receptacle checked by a qualified electrician before connecting this equipment. 
Do not cut or remove the third (ground) prong from the power transformer. Do not use two-prong 
extension cords or adapters to defeat the safety features of this equipment. If you have a two-prong 
receptacle, it must be replaced with a three-prong receptacle, installed by a qualified electrician.

9. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be 

abused by persons walking on it.

10. Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.
11. Never push objects of any kind into this product through cabinet slots as they may touch dangerous 

voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of 
any kind on the product.

12. To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified service-

man when some service or repair work is required. Opening or removing covers may expose you to 
dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the 
appliance is subsequently used.

Technical Manuals Online! - http://www.tech-man.com

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Summary of Contents for PagePac 6 Plus

Page 1: ...telephone systems from single line residential systems to electronic key and PBX systems SPECIFICATIONS FEATURES Works with either one or two lines and provides two separate paging accesses when used...

Page 2: ...or heat register This product should not be placed in a built in installation unless proper ventilation is provided 7 This product should be operated only from the type of power source indicated on t...

Page 3: ...ak SAVE THESE INSTRUCTIONS GENERAL INFORMATION Please adhere to the following precautions 1 Never install telephone wiring during a lightning storm 2 Never install telephone jacks in wet locations unl...

Page 4: ...ary head set Anything greater than this can harm the PagePac 6 Plus and void the warranty Single Line Use Line 1 Connection Only 1 Install the first connecting block and attach the incoming line s to...

Page 5: ...equipment Do not cut or remove the third ground prong from the power cord Do not use two wire extension cords or adapters to defeat the safety features of this equipment If you have a two prong recept...

Page 6: ...O N M u s i c Z o n e 2 O N M u s i c Z o n e 3 O N M u s i c A l l Z o n e s O F F T a l k b a c k L i n e 1 O F F T a l k b a c k L i n e 2 O F F T a l k b a c k L i n e s 1 2 O N T a l k b a c k Z...

Page 7: ...Line 1 OFF Talkback on LIne 2 OFF Talkback on Lines 1 and 2 ON 891 892 893 Talkback in Zone 1 OFF Talkback in Zone 2 OFF Talkback in Zone 3 OFF Talkback in all zones ON 821 822 823 824 Initial talkba...

Page 8: ...hone controls the page talkback switch If this person speaks or makes any noise anyone using talkback will be cut off After the person at the telephone is quiet it takes about one half second for the...

Page 9: ...ic Outside Line Access should be set for 2 seconds Dial option code 862 for Line 1 or 866 for Line 2 1 Lift the telephone handset on a key system select the desired line and wait for the regular dial...

Page 10: ...e several types of installation and maintenance plans available from Valcom or your dealer For information or warranty service call your Valcom sales representative or authorized dealer To adjust pagi...

Page 11: ...ll 70 volt speakers with voice coil type Music does not work but paging does Check music volume control on rear of paging unit Adjust volume control on music source Check the programming options Do no...

Page 12: ...ice Washington DC 20402 Stock order No 004 000 00345 4 FCC Part 68 This equipment is registered with the Federal Communications Commission FCC in accordance with Part 68 of its Rules The FCC requires...

Page 13: ...ssociated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above conditio...

Page 14: ...one lines that may be exposed to high voltage power lines Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designe...