background image

4

947182

Installation Procedure

1. Connect PagePac® 6 Plus to the incoming telephone line(s). Connections are shown in Figure 2.
2. Connect PagePac 6 Plus to line jack(s) on telephone system.
3. Connect speakers to PagePac 6 Plus with RCA-type phono plugs and “B” crimp-type wire             

connectors (provided).

4. (Optional) You may connect an external music source such as a FM tuner, tape deck, leased source, 

etc. 

5. Connect the power supply to an AC outlet (120 VAC, 60 Hz). The LED on the PagePac 6 Plus back 

panel (below the power cord) will illuminate.

NOTE:

  If optional music source is used, it must have a 600 Ohm less than 1 volt output to drive the 

PagePac 6 Plus (usually the output that would drive an auxiliary head set). Anything greater than this 
can harm the PagePac 6 Plus and void the warranty.

Single Line—Use Line 1 Connection Only

1. Install the first connecting block and attach the incoming line(s) to the block.
2. Attach the half-modular connecting block, and connect the other end to the PagePac 6 Plus 

(see Figure 2).

3. Install the second connecting block and attach the line(s) to the telephone(s).
4. Attach the second half-modular cord to this block and connect the other end to the Pagepac 6 Plus.

Figure 2.

  Attaching the Half-Modular Cord

WRAP UNUSED WIRE
AROUND CABLE

TYPE 42A CONNECTING BLOCK

RED

G

R

B

Y

GREEN

RED

GREEN

LINE 1

LINE 2

TO
CENTRAL
OFFICE

YELLOW
LINE 2

BLACK
LINE 2

RED

GREEN

HALF MODULAR CORD

TP PAGEPAC 6 PLUS
"TO TEL. CO. J4"

UL 497A
SECONDARY
PROTECTORS

Technical Manuals Online! - http://www.tech-man.com

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Summary of Contents for PagePac 6 Plus

Page 1: ...telephone systems from single line residential systems to electronic key and PBX systems SPECIFICATIONS FEATURES Works with either one or two lines and provides two separate paging accesses when used...

Page 2: ...or heat register This product should not be placed in a built in installation unless proper ventilation is provided 7 This product should be operated only from the type of power source indicated on t...

Page 3: ...ak SAVE THESE INSTRUCTIONS GENERAL INFORMATION Please adhere to the following precautions 1 Never install telephone wiring during a lightning storm 2 Never install telephone jacks in wet locations unl...

Page 4: ...ary head set Anything greater than this can harm the PagePac 6 Plus and void the warranty Single Line Use Line 1 Connection Only 1 Install the first connecting block and attach the incoming line s to...

Page 5: ...equipment Do not cut or remove the third ground prong from the power cord Do not use two wire extension cords or adapters to defeat the safety features of this equipment If you have a two prong recept...

Page 6: ...O N M u s i c Z o n e 2 O N M u s i c Z o n e 3 O N M u s i c A l l Z o n e s O F F T a l k b a c k L i n e 1 O F F T a l k b a c k L i n e 2 O F F T a l k b a c k L i n e s 1 2 O N T a l k b a c k Z...

Page 7: ...Line 1 OFF Talkback on LIne 2 OFF Talkback on Lines 1 and 2 ON 891 892 893 Talkback in Zone 1 OFF Talkback in Zone 2 OFF Talkback in Zone 3 OFF Talkback in all zones ON 821 822 823 824 Initial talkba...

Page 8: ...hone controls the page talkback switch If this person speaks or makes any noise anyone using talkback will be cut off After the person at the telephone is quiet it takes about one half second for the...

Page 9: ...ic Outside Line Access should be set for 2 seconds Dial option code 862 for Line 1 or 866 for Line 2 1 Lift the telephone handset on a key system select the desired line and wait for the regular dial...

Page 10: ...e several types of installation and maintenance plans available from Valcom or your dealer For information or warranty service call your Valcom sales representative or authorized dealer To adjust pagi...

Page 11: ...ll 70 volt speakers with voice coil type Music does not work but paging does Check music volume control on rear of paging unit Adjust volume control on music source Check the programming options Do no...

Page 12: ...ice Washington DC 20402 Stock order No 004 000 00345 4 FCC Part 68 This equipment is registered with the Federal Communications Commission FCC in accordance with Part 68 of its Rules The FCC requires...

Page 13: ...ssociated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above conditio...

Page 14: ...one lines that may be exposed to high voltage power lines Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designe...

Reviews: