2
947167
5. Do not replace the plastic cover until final
power adjustments have been made.
FINAL POWER ADJUSTMENTS
While a page is in process, adjust the power tap
setting control with a screwdriver. Turn clockwise
to increase the volume (see Figure 2).
NOTE
: Protect hearing when working around
horns.
FIGURE 1
TECHNICAL ASSISTANCE
When calling, have a VOM and a telephone test
set available and call from the job site. Call (540)
427-3900 and ask for PagePac Technical Sup-
port, or call (540) 427-6000 for Valcom 24-hour
Automated Support or visit our websites at
http://www.pagepac.com and www.valcom.com.
Should repairs be necessary, attach a tag to the
unit clearly stating company name, address,
phone number, contact person, and the nature of
the problem. Send the unit to:
Valcom, Inc.
PagePac
®
Repair Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
FIGURE 2
MOUNTING ON FLAT SURFACE
WING NUT
MOUNTING
BRACKET
Table 1: 15 WATT SETTINGS
SWITCH
SETTING
70V
TAP
SETTINGS
25V
TAP
SETTINGS
1
0.25
--
2
0.50
--
3
0.90
--
4
1.80
.225
5
3.80
.475
6
7.50
.93
7
15.0
1.87
Table 2: 30 WATT SETTINGS
SWITCH
SETTING
70V
TAP
SETTINGS
25V
TAP
SETTINGS
1
1.2
.15
2
2.5
.31
3
5.0
.62
4
7.5
.93
5
15.0
1.87
6
30
3.75
Technical Manuals Online! - http://www.tech-man.com
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com