background image

 

 

 

 

 

 

 

 

2 947100 

VoIP  (Voice-over-Internet-Protocol) 
Adapters 

 

Valcom’s VoIP adapters provide loudspeaker 
paging through the client’s LAN/WAN.

 

 

VIP-800, Networked Audio Port, enables voice 
access over an IP-based LAN/WAN. Other VIP-
800(s) will allow page zone extensions anywhere 
else on the network.

 

 

VIP-810, Networked Station Port, connects to an 
FXO port, loop start trunk port, or dedicated 
analog telephone terminal device, and is connected 
to an IP-based LAN/WAN.

 

 

VIP-820, Networked Trunk Port, allows a PBX 
system device or IP telephone adapter to be 
connected to a managed IP-based LAN/WAN.  
The PBX system

 

device or IP telephone adapter 

must provide an open loop disconnect signal.

 

 

UP to 99 zones are possible using a VIP-800 unit 
per zone for audio output.

 

 

Dimensions 

V-1094A: 

4.44"H x 2.75"W x 2.88"D 

 

(11.28cm x 6.99cm x 7.32cm) 

V-2000A: 

7.75"H x 5.8"W x 2.6"D 

 

(19.69cm x 14.73cm x 6.6cm) 

V-2001A: 

7.09"H x 9.0"W x 2.4"D 

 

(18.0cm x 22.86cm x 6.1cm) 

V-2003A: 

7.13"H x 10.00"W x 3.00"D 

 

(18.1cm x 25.4cm x 7.62cm) 

V-2006A: 

10.9"H x 13.00"W x 2.69"D 

 

(27.7cm x 33.0cm x 6.83cm) 

V-2924A: 

17.5"H x 10.3"W x 3.06"D 

 

(44.45cm x 26.26cm x 7.77cm) 

V-2925A: 

17.5"H x 8.37"W x 3.06"D 

 

(44.45cm x 21.26cm x 7.77cm) 

V-2926: 

5.3"H x 3.0"W x 1.1"D 

 

(13.46cm x 7.620cm x 2.79cm)  

V-292

8

: 5.3"H x 3.0"W x 1.1"D 

 

(13.46cm x 7.620cm x 2.79cm) 

V-1109RTVA: 

7.13"H x 5.9"W x 2.13"D 

 

(18.11cm x 14.99cm x 5.41cm) 

VIP-800: 

1.88”H x 5.50”Wx 4.15”D 

 

(4.78cm x 13.97cm x 10.54cm) 

VIP-810: 

1.88”H x 5.50”Wx 4.15”D 

 

(4.78cm x 13.97cm x 10.54cm) 

VIP-820: 

1.88”H x 5.50”Wx 4.15”D 

 

(4.78cm x 13.97cm x 10.54cm) 

 
 
 
 

Environment 
 

Control Units: 
 

Temperature 

0 to +40 degrees C 

 Humidity 

0-85% 

non-precipitating 

 
Inside Speakers: 
 

Temperature 

-20 to +55 degrees C 

 

Humidity 

0-95% non-Precipitating  

 
Horn Speakers: 
 

Temperature 

-20 to +55 degrees C 

 Humidity 

0-95% 

non-precipitating 

 

Control Unit Power Requirements 
 

Table 1 

Control Unit 

"A"  Battery 

"B" Battery 

VPU 

V-1094A - 

50 

mA 

-1 

V-1101A 

50 mA 

100 mA 

-3 

V-2000A 

Supplies 600 milliamps, filtered 

+12 

V-2001A 

Supplies 1 Amp, filtered 

+20 

V-2003A 

Supplies 1.Amp, filtered 

+20 

V-2006A Supplies 

1.5 

Amp, filtered 

+30 

V-2924A/V-2925A 

A. C. Line Powered 

V-1109RTVA 

60 mA 

250 mA 

-6 

 

VIP- 800/810/820 

Power Supply Included 

 
Notes for Table 1: 

"A" Battery: 

-21.5 to -26VDC filtered "talk" battery 

"B" Battery: 

-21.5 to -25VDC unfiltered "signal" battery 

 

Filtered "A" battery may be used as both "A" battery 
and "B" battery. 
 
Unfiltered "B" battery may not be used in place of 
filtered "A" battery. 
 
VPU = Valcom Power Unit. 
 

Summary of Contents for V-1094A

Page 1: ...ectronic Key System line button C O circuit required PABX loop trunk port trunk circuit required Page port Station level access available with appropriate adapter Stand alone with dedicated single lin...

Page 2: ...77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 2928 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 1109RTVA 7 13 H x 5 9...

Page 3: ...er black vinyl cover V 1016 BK Wall Speaker white vinyl cover V 1016 W 8 Ceiling Speaker V 1020C 8 Ceiling Speaker with knob V 1020KNOB 8 Ceiling Speaker with plastic grille V 1021C Wall Speaker lt br...

Page 4: ...ace speaker and peripheral device has been assigned a Valcom power unit VPU value Products that provide power such as the 2000 Series page control interfaces or power supplies have power unit values i...

Page 5: ...nection to the public telephone network and also carry U L 1459 approval It will ring trip from 70 to 105 VRMS 20 to 30 hertz ringing voltage With a single line telephone the called party provides the...

Page 6: ...ack or mounting frames A 66 type and 25 pair pigtail with female amphenol connector are required for connections to these units if the mounting frames are not used Other control units are wall mount u...

Page 7: ...ipping areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very diffi...

Page 8: ...e system plus a preamplifier circuit and in some cases dial select circuitry and or provisions for background music switching Each one way amplified speaker assembly contains a speaker amplifier and v...

Page 9: ...ply is required for V 9934 Up to four v 9934 units may be paralleled on one V 9933A Each V 9934 may be on a 1000 wire run Stacking Feedback Eliminator The V 9964 Stacking Feedback Eliminator is design...

Page 10: ...f 96 zones from a single trunk port Up to 576 Zones with All Call with multiple systems connected for Global All Call Call Valcom Technical Support for assistance Talkback one way or combination syste...

Page 11: ...M 5 V 9915 5 Or V 9915M 5 V 9916 Or V 9916M X X V 1021C V 9918 V 9915 5 V 1021C V 9914 5 V 9915 5 V 9916 X V 1420 V 9816M X The V 9914 5 Bridge and the V 9915 5 Backbox are made of Borg Warner Flamex...

Page 12: ...X X X X Night Ringing Tones X X X Add V 9927A X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input X X X X Inhibit Speaker Cancel X X X X Loop St...