background image

 

 

 

 

 

 

 

 

8 947100 

Table 8 - Number of Speakers per Power Run 

(CAT 3/5/5E/6,  22 & 24 AWG) 

 

Quantity of Speakers/Horns 

Maximum 

Wire Run 

Distance (Ft) 

1 Watt 

Interior 

Speakers 

Signature 

Series 

5W 

15W 
30W 

24 

AWG 

22 

AWG


15 
30 








1000 

500 
250 
125 

1600 

800 
400 
200 

 

 

Bridges and Backboxes 

Ceiling speaker bridges provide support to prevent 
ceiling tile from sagging from the weight of the 
speaker.  They are designed for use with standard 2' 
wide ceiling tiles and distribute the weight of the 
speaker assembly across the tile and onto the tile 
support grid. 
 
Ceiling speaker backboxes provide an acoustic 
enclosure behind the speaker for better sound quality.  
They also protect the speaker from debris in the ceiling 
and meet most local fire codes for use in air plenum 
return ceilings.  See Table 9 for Speaker and 
Bridge/Backbox compatibility. 
 

Volume Adjustments 

Master volume controls are located on most Valcom 
page control units.  Each one-way speaker assembly 
also has its own volume control.  When installing a 
system, set the master control to 1/2 and all speaker 
and horn volume controls to 1/2 volume.  After 
powering up the system, adjust the individual speakers 
to the desired level. 
 
The master control may then be used to change the 
volume of the entire system.  If background music is 
being supplied, the background music level should be 
adjusted last.  To provide volume control to a certain 
room or area, V-1092 Wall Mount Volume Controls 
may be added to a zone, or to a section of a zone. 

SYSTEM OPERATION 
Circuit Description 

Each Valcom page control unit contains the circuitry 
required to interface with a telephone system, plus a 
preamplifier circuit, and in some cases dial select 
circuitry and/or provisions for background music 
switching.  Each one-way amplified speaker assembly 
contains a speaker, amplifier, and volume control in a 
suitable baffle or housing.  The speakers and control 
units require a -24VDC power supply (-48VDC for the 
V-1038) to operate. 
 
Connections from the control unit to the telephone 
system are described in detail in the manual that is 
shipped with the control unit. 
 
The audio pair from the control unit to the speakers 
may be looped (speakers wired in parallel) between all 
speakers in a zone (See Table 7).  A second pair must 
be run to each speaker to supply the DC voltage 
required for operation (See Table 11).  Standard 22 or 
24AWG telephone cable may be used for the speakers. 
 
When accessing a single zone control unit from the 
telephone system, you will immediately be connected 
to the speakers and allowed to page. 
 
When accessing a multizone control unit from the 
telephone system, you will receive Valcom dial tone 
from the Valcom unit.  After dialing the code for the 
zone desired, you will be connected to that group of 
speakers and allowed to page.  All Valcom control 
units automatically release when you hang up the 
telephone. 
 

TECHNICAL ASSISTANCE 

Refer to the installation practices for the equipment 
being used for troubleshooting information and 
procedures.

 

Assistance in troubleshooting is available 

from the factory.  Call (540) 563-2000 and press 1 for 
Technical Support. 
 
Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the unit 
clearly stating company name, address, phone number, 
contact person, and nature of the problem.  Send the 
unit to: 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, VA 24019-5056

 

Summary of Contents for V-1094A

Page 1: ...ectronic Key System line button C O circuit required PABX loop trunk port trunk circuit required Page port Station level access available with appropriate adapter Stand alone with dedicated single lin...

Page 2: ...77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 2928 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 1109RTVA 7 13 H x 5 9...

Page 3: ...er black vinyl cover V 1016 BK Wall Speaker white vinyl cover V 1016 W 8 Ceiling Speaker V 1020C 8 Ceiling Speaker with knob V 1020KNOB 8 Ceiling Speaker with plastic grille V 1021C Wall Speaker lt br...

Page 4: ...ace speaker and peripheral device has been assigned a Valcom power unit VPU value Products that provide power such as the 2000 Series page control interfaces or power supplies have power unit values i...

Page 5: ...nection to the public telephone network and also carry U L 1459 approval It will ring trip from 70 to 105 VRMS 20 to 30 hertz ringing voltage With a single line telephone the called party provides the...

Page 6: ...ack or mounting frames A 66 type and 25 pair pigtail with female amphenol connector are required for connections to these units if the mounting frames are not used Other control units are wall mount u...

Page 7: ...ipping areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very diffi...

Page 8: ...e system plus a preamplifier circuit and in some cases dial select circuitry and or provisions for background music switching Each one way amplified speaker assembly contains a speaker amplifier and v...

Page 9: ...ply is required for V 9934 Up to four v 9934 units may be paralleled on one V 9933A Each V 9934 may be on a 1000 wire run Stacking Feedback Eliminator The V 9964 Stacking Feedback Eliminator is design...

Page 10: ...f 96 zones from a single trunk port Up to 576 Zones with All Call with multiple systems connected for Global All Call Call Valcom Technical Support for assistance Talkback one way or combination syste...

Page 11: ...M 5 V 9915 5 Or V 9915M 5 V 9916 Or V 9916M X X V 1021C V 9918 V 9915 5 V 1021C V 9914 5 V 9915 5 V 9916 X V 1420 V 9816M X The V 9914 5 Bridge and the V 9915 5 Backbox are made of Borg Warner Flamex...

Page 12: ...X X X X Night Ringing Tones X X X Add V 9927A X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input X X X X Inhibit Speaker Cancel X X X X Loop St...

Reviews: