background image

 

 

 

 

 

 

 

 

9 947100 

PROBLEM SOLVERS 
Automatic Volume Control 

The V-9933A Noise Sensing Volume Control monitors 
the noise level fluctuations in an area by utilizing a 
built-in microphone.  When a page is made, the 

V-

9933A electronically locks onto the last noise level 

sampled and automatically adjust the volume of up to 
150 Valcom One-Way Self-Amplified Speakers in 
order to compensate for the current ambient noise 
level, thus eliminating the need for personnel to 
manually adjust the paging speakers.  The V-9933A 
should be mounted in the area that experiences the 
fluctuating noise.  If a single zone contains areas of 
independently fluctuating noise levels, multiple V-
9933A units may be used (one per area). 

 

Each Noise Sensing Volume Control, V-9933A, 
can control up to 150 amplified speakers or horns 
in a single zone. 

 

Multiple Noise Sensing Volume Controls, V-
9933A, can be used on the same zone if desired. 

 

V-9933A can be connected to a zone output of any 
Valcom One-Way Page Control/Interface or 
Station Level Page Control. 

 

Not for use with background music without 
additional equipment. 

 

Remote Microphone 

The V-9934 Remote Microphone may be used with  
the V-9933A Noise Sensing Volume Control. 

 

V-9934 is a self-contained microphone and pre-
amp. 

 

No power supply is required for V-9934 

 

Up to four v-9934 units may be paralleled on one 
V-9933A. 

 

Each V-9934 may be on a 1000’ wire run.    

Stacking Feedback Eliminator 

The V-996

4

, Stacking Feedback Eliminator, is 

designed to prevent paging system feedback.  When a 
page is made into a zone, the V-9964 records the page 
into digital memory.  Upon completion of the live 
page, the message is released to play over the zone of 
speakers.  Since the paging party has hung up the 
telephone or released the microphone, offensive 
feedback cannot occur. 

 

Each Stacking Feedback Eliminator, V-9964, can 
control up to 150 amplified speakers or horns in a 
single zone. 

 

Multiple Stacking Feedback Eliminators, V-9964, 
can be used on multiple zone page controls. 

 

The V-9964 can be connected to a zone output of 
any Valcom One-Way Page Control/Interface or 
Station Level Page Control. 

 
 

ENHANCEMENT TO EXISTING 
25/70/100 VOLT PAGING 
SYSTEMS 

Using a Valcom Page Control/Interface 
with a Central Amplifier 

Typically a zone from a one-way control unit may be 
directly connected to a high power amplifier to allow 
access to existing paging equipment.  In certain cases 
capacitors or a resistor network may be required to 
interface the Valcom equipment to the amplifier.  
Contact Valcom Technical Support if trouble is 
encountered. 

NOTE:  Not all Valcom page control units have 
control leads available for amplifier control. 
Use Valcom One-Way Self-Amplified Speakers to 
expand a 25/70/100V audio zone.

Summary of Contents for V-1094A

Page 1: ...ectronic Key System line button C O circuit required PABX loop trunk port trunk circuit required Page port Station level access available with appropriate adapter Stand alone with dedicated single lin...

Page 2: ...77cm V 2925A 17 5 H x 8 37 W x 3 06 D 44 45cm x 21 26cm x 7 77cm V 2926 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 2928 5 3 H x 3 0 W x 1 1 D 13 46cm x 7 620cm x 2 79cm V 1109RTVA 7 13 H x 5 9...

Page 3: ...er black vinyl cover V 1016 BK Wall Speaker white vinyl cover V 1016 W 8 Ceiling Speaker V 1020C 8 Ceiling Speaker with knob V 1020KNOB 8 Ceiling Speaker with plastic grille V 1021C Wall Speaker lt br...

Page 4: ...ace speaker and peripheral device has been assigned a Valcom power unit VPU value Products that provide power such as the 2000 Series page control interfaces or power supplies have power unit values i...

Page 5: ...nection to the public telephone network and also carry U L 1459 approval It will ring trip from 70 to 105 VRMS 20 to 30 hertz ringing voltage With a single line telephone the called party provides the...

Page 6: ...ack or mounting frames A 66 type and 25 pair pigtail with female amphenol connector are required for connections to these units if the mounting frames are not used Other control units are wall mount u...

Page 7: ...ipping areas or light manufacturing Noisy 80 90dB This includes machine shops or heavy manufacturing Very Noisy Greater than 90dB This would include areas where talking to another person is very diffi...

Page 8: ...e system plus a preamplifier circuit and in some cases dial select circuitry and or provisions for background music switching Each one way amplified speaker assembly contains a speaker amplifier and v...

Page 9: ...ply is required for V 9934 Up to four v 9934 units may be paralleled on one V 9933A Each V 9934 may be on a 1000 wire run Stacking Feedback Eliminator The V 9964 Stacking Feedback Eliminator is design...

Page 10: ...f 96 zones from a single trunk port Up to 576 Zones with All Call with multiple systems connected for Global All Call Call Valcom Technical Support for assistance Talkback one way or combination syste...

Page 11: ...M 5 V 9915 5 Or V 9915M 5 V 9916 Or V 9916M X X V 1021C V 9918 V 9915 5 V 1021C V 9914 5 V 9915 5 V 9916 X V 1420 V 9816M X The V 9914 5 Bridge and the V 9915 5 Backbox are made of Borg Warner Flamex...

Page 12: ...X X X X Night Ringing Tones X X X Add V 9927A X Time Clock Tones X X X Add V 9927A X Power Supply Built In X X X X X Group Call X X Battery Back up Input X X X X Inhibit Speaker Cancel X X X X Loop St...