background image

 

2  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM DESIGN

 

Telephone System Requirements

 

The V-9937 is designed to work with telephone 
system

 

page ports, which provide an audio pair (8 

to 600 Ohms) and a dry contact closure for 
control.  This will be referred to as 

Arrangement 

1.

 

The V-9937 may also be used with page ports (8 
to 600 Ohms) that do not have control leads, with 
two feature limitations: 

 

1

) If background music is desired, the telephone  

    system must be capable of providing the 
    switching instead of the V-9937; 

 
  2) 

The AGC and pop suppression circuitry will not 

      be enabled on a standard page (they will still 
    work on page override).  This will be referred to 
     as 

Arrangement 2. 

 

NOTE:  Refer to the Installation section for 
Arrangement 1 and 2 connecting information. 

 

Equipment

 

A complete one zone one-way page system using 
the V-9937 will be made up of the following:

 

 

Telephone system page card (if page ports 
are not standard)

 

  V-9937 page port adapter 

  Valcom one-way amplified speaker 

assemblies (or existing high power amplifier 
and speakers) 

  -24VDC power supply 

 

Optional (depending on individual job 
requirements): 

 Music 

source 

  V-9942 Tone Module 

INSTALLATION 

Instructions

 

The following sections contain step by step 
instructions for wiring the V-9937.  Each 
instruction is preceded by a line.  Place a check on 
the appropriate line as the instruction is 
completed.  The instructions also include tests 
along the way to verify connections have been 
made correctly.  If these steps are followed 
exactly, installation of your Valcom system will go 
smoothly and quickly.  If the results of a test do not 
correspond with what is shown, 

do not proceed 

until the problem has been corrected.

 

 

NOTE:  The telephone system referred to in 
this manual is the customer premise 
equipment such as an electronic key system, a 
PABX or a dedicated single line telephone (s).  
The V-9937 is not intended for direct or indirect 
connection to the public telephone network or 
to PABX analog station ports.  When used with 
a customer premise telephone system such as 
a key system or PABX system, these units are 
interfaced to the system via a fully protected 
page port or system central office port, which 
is a fully protected interface device.  Also, the 
host system must be configured to disallow 
central office trunk conferencing in order to 
prevent indirect connection to the public 
network. 

 
 
 
 
 
 

Electronic
Key System

C. O. Line
    Port

V-9937

Music
Source

Power
Supply

FIGURE 1 - SIMPLIFIED BLOCK DIAGRAM OF A TYPICAL INSTALLATION

One-Way Amplified
Speaker Assemblies

  Page Port

Contact
Closure

Input 1

Input 2

Control

Input 3

(Arrangement 1)

Output 1

Pwr

Output 2

Pwr

Page
   +
Music

Page
Only

Summary of Contents for V-9937

Page 1: ...ain control Pop suppression Override capability using C O line position or PABX loop trunk port Low level input for background music typically 17dBm Automatic background music cutoff when the page por...

Page 2: ...V 9937 Each instruction is preceded by a line Place a check on the appropriate line as the instruction is completed The instructions also include tests along the way to verify connections have been m...

Page 3: ...ng Remove the metal mounting plate from the rear of the V 9937 enclosure Using two 6 inch wood screws mount the plate in a vacant space on the backboard with the telephone system common equipment Both...

Page 4: ...ECTING BLOCK POINTS Wiring Arrangements 1 and 2 Refer to Figure 2 for location and numbering of connection block and Figure 3 for connecting block pin outs ___ 1 Unplug power supply ___ 2 Connect 24VD...

Page 5: ...ack lead of horns NOTE Set speaker volume controls at approximately 1 2 volume during installation Volume Adjustment and Test Refer to Figure 4 for location of volume controls Test the system and adju...

Page 6: ...nd pop suppression circuits Accessing this port will override inputs 2 and 3 Input 2 is transformer coupled to the V 9937 Ground must be applied to pin 3 for this input to operate provided from pin 18...

Page 7: ...ch defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the orig...

Page 8: ...NOT MARKED OPTIONAL MUST BE COMPLETED V 9937 CONNECTING BLOCK FIGURE 5 WIRING CONNECTIONS FOR ARRANGEMENT 1 PAGE ONLY PAGE PLUS MUSIC 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21...