background image

 

 

 

 

 

16

 

30

 

1

 

15

 

Power

 

Reversal
Indicator

 

1

 

8

 

ON

 

OFF

 

Dip

 

Switches

FIGURE 2

 

       

LOCATION AND NUMBERING OF

 

PUNCHDOWN BLOCK AND DIP SWITCHES

 

Punchdown

 

Block

 

15 14 13 12 11 10  9 8  7  6  5  4  3  2  1

FIGURE 3 - PUNCHDOWN BLOCK PINOUTS

AUX GND TERM.

AUX -24VDC OUT TERM

ALL CALL O

U

T

MANUAL RESET

8 OHM PAGE OUT

600 OHM PAGE OUT

BREAK

STATIONARY

MAKE

of the unit

.

 Provisions for mounting to a single 

or double gang junction box are provided. 
See Figure 5. 

 

Open the V-9940 enclosure to allow access to 
connections and option switches.  Slide the rear 
of the unit (contains the board) onto the 
mounting plate.  Lock enclosure to mounting 
plate with screw provided.  Make connections.  
Replace cover and lock in place with #6 ½ inch 
screws provided. 
 

Power Connections 

NOTE

:  

Power is required for each V-9940 

being used.  If multiple units are used, power 
for additional units may be multiplied from 
pins 14 and 15 of a previous unit (pin 14 is 
"+" and pin 15 is "-"). 

 

  Unplug power supply. 

  Connect -24VDC "B" battery (may be 

referred to as "-" or "signal battery") from 
power supply to pin 30 on V-9940 and "B" 
ground "+" or "signal" ground) from power 
supply to pin 29. 

  Connect -24VDC Ground from power supply 

to telephone system Ground. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

               Figure 4 Dip Switch Settings 

 
 
 
 
 
 
 
 
 
 
 
 
 

 Power 

Test: 

  a.  Plug in power supply. 

  b.  If power reversal LED is lit: 

1. 

Unplug power supply. 

2. 

Reverse connections on pins 29, 30. 

Repeat step 5. 

  Unplug power supply. 

 

PABX Connecting Arrangements: 

NOTE:  From the list below, determine the 
arrangement being used and proceed to the 
Figure indicated for step-by-step 
instructions. 

  One Zone of One-Way Paging:  Go to 

Figure 6. 

  Multi-Zone One-Way Paging with All Call 

(Multiple Talkpaths):  Go to Figure 7. 

  One Zone of Handsfree Paging:  Go to 

Figure 8. 

SW

 

OFF

 

ON

 

 

 

1

 

 Audio Sense

 

 

     Enable

 

      Time Out

 

 

 

        Enable

 

 

 

2

 

  Not 1 Sec.

 

     1 Second

 

 

 

3

 

  Not 64 Sec.

 

    64 Seconds

 

 

 

4

 

  Not 32 Sec.

 

    32 Seconds

 

 

 

5

 

  Not 16   Sec.

 

    16 Seconds

 

 

 

6

 

   Not 8 Sec.

 

      8 Seconds

 

 

 

7

 

   Not 4 Sec.

 

      4 Seconds

 

 

 

8

 

  Loop Detect

 

 

     Disable

 

    Loop Detect

 

 

 

        Enable

 

 

 

 

8

 

7

 

 

 

6

 

 

 

5

 

 

 

4

 

 

 

3

 

2

 

1

 

OFF

 

ON

 

Summary of Contents for V-9940

Page 1: ...vide the best service possible In order to do this it may occasionally be necessary for them to make changes in their equipment operations or procedures If these changes potentially affect the service...

Page 2: ...22dBm Time Out Release 1 4 8 16 32 or 64 seconds Manual Reset 25ms ground Output 1 Impedance 600 Ohms Page Level Output Level Input Level 1dB Music Level Output Level Input Level Output 2 Impedance 8...

Page 3: ...Assemblies and a 24VDC power supply NOTE All Call is included with the V 2003A V 2006A and the V 1109RTVA It may be added to the V 119RTVA with a V 1118 and to the V 136RTHF with a V 1134 See Note One...

Page 4: ...PABX is compatible for station level page When used with talkback paging the talkback audio may delay or cancel the audio sense release In some special applications a manual reset can be used to provi...

Page 5: ...s 14 and 15 of a previous unit pin 14 is and pin 15 is Unplug power supply Connect 24VDC B battery may be referred to as or signal battery from power supply to pin 30 on V 9940 and B ground or signal...

Page 6: ...L MOUNTING PLATE WIREWAY OPENING TO WALL PLATE AND JUNCTION BOX WIRE TIE LOOP WIRE TIE USED TO BUNDLE WIRES ENTERING AND LEAVING TERMINAL AREA SNAP LATCH FOR COVER 155 DIA HOLES FOR MOUNTING TO SINGLE...

Page 7: ...E ACCESS V 9940 CONNECTION BLOCK WIRING INSTRUCTIONS Place a check by each step as it is completed ____ 1 Connect Tip of the PABX Centrex or C O Line to pin 16 and Ring to Pin 17 of the V 9940 ____ 2...

Page 8: ...the V 9940s being used for individual zones ____3c Strap from pin 13 of the all call V 9940 to pin 28 of each of the V 9940s being used for individual zones ____ 4 Music Input Background music may be...

Page 9: ...e length ____ 7b Centrex or C O Line access Set switches 1 and 8 ON Set switches 2 through 7 all OFF See section titled Dip Switch Settings for additional information regarding dip switches ____ 8 Ref...

Page 10: ...o 7 all OFF See Section titled Dip Switch Settings for additional information regarding dip switches ____ 8 When all connections are complete replace cover and lock in place using the 6 inch screws pr...

Page 11: ...aging in progress will be overridden and an alert tone will be returned to the overridden parties If they remain on line on completion of the all call page they will be reconnected to their respective...

Page 12: ...the event a product is received in damaged condition the carrier should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the F O B point Head...

Reviews: