background image

 

 

6

 

 

 
 

 
 

FIGURE 5 

MOUNTING 

EXPLODED VIEW 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

TO REMOVE COVER
LOOSEN SCREW,
THEN ACTIVATE LATCH

PLASTIC
COVER

CIRCUIT BOARD
HOUSING ASSEMBLY

SNAP LATCH

METAL WALL
MOUNTING

PLATE

WIREWAY OPENING
TO WALL PLATE AND
JUNCTION BOX

WIRE TIE LOOP
WIRE TIE USED TO BUNDLE WIRES
ENTERING AND LEAVING TERMINAL AREA

SNAP LATCH
FOR COVER

.155 DIA. HOLES FOR MOUNTING TO
SINGLE OR DOUBLE GANG JUNCTION BOX
HOLE PATTERN MATCHES BOTH EURO 
AND US JUNCTION BOXES

1.5 x 2 WIRE ACCESS OPENING
TO JUNCTION BOX

BRACKET

LOCKING
SCREW

Summary of Contents for V-9940

Page 1: ...vide the best service possible In order to do this it may occasionally be necessary for them to make changes in their equipment operations or procedures If these changes potentially affect the service...

Page 2: ...22dBm Time Out Release 1 4 8 16 32 or 64 seconds Manual Reset 25ms ground Output 1 Impedance 600 Ohms Page Level Output Level Input Level 1dB Music Level Output Level Input Level Output 2 Impedance 8...

Page 3: ...Assemblies and a 24VDC power supply NOTE All Call is included with the V 2003A V 2006A and the V 1109RTVA It may be added to the V 119RTVA with a V 1118 and to the V 136RTHF with a V 1134 See Note One...

Page 4: ...PABX is compatible for station level page When used with talkback paging the talkback audio may delay or cancel the audio sense release In some special applications a manual reset can be used to provi...

Page 5: ...s 14 and 15 of a previous unit pin 14 is and pin 15 is Unplug power supply Connect 24VDC B battery may be referred to as or signal battery from power supply to pin 30 on V 9940 and B ground or signal...

Page 6: ...L MOUNTING PLATE WIREWAY OPENING TO WALL PLATE AND JUNCTION BOX WIRE TIE LOOP WIRE TIE USED TO BUNDLE WIRES ENTERING AND LEAVING TERMINAL AREA SNAP LATCH FOR COVER 155 DIA HOLES FOR MOUNTING TO SINGLE...

Page 7: ...E ACCESS V 9940 CONNECTION BLOCK WIRING INSTRUCTIONS Place a check by each step as it is completed ____ 1 Connect Tip of the PABX Centrex or C O Line to pin 16 and Ring to Pin 17 of the V 9940 ____ 2...

Page 8: ...the V 9940s being used for individual zones ____3c Strap from pin 13 of the all call V 9940 to pin 28 of each of the V 9940s being used for individual zones ____ 4 Music Input Background music may be...

Page 9: ...e length ____ 7b Centrex or C O Line access Set switches 1 and 8 ON Set switches 2 through 7 all OFF See section titled Dip Switch Settings for additional information regarding dip switches ____ 8 Ref...

Page 10: ...o 7 all OFF See Section titled Dip Switch Settings for additional information regarding dip switches ____ 8 When all connections are complete replace cover and lock in place using the 6 inch screws pr...

Page 11: ...aging in progress will be overridden and an alert tone will be returned to the overridden parties If they remain on line on completion of the all call page they will be reconnected to their respective...

Page 12: ...the event a product is received in damaged condition the carrier should be notified immediately Claims for such damage should be filed with the carrier involved in accordance with the F O B point Head...

Reviews: