background image

Valcom, Inc.
5614 Hollins Road
Roanoke, VA  24019

540-563-2000 P.
540-362-9800 F.
www.valcom.com

11

Installation Instructions

Plastic Double Mount Installation

 

Snap and screw base to metal mounting bracket - 

Snap the base to the metal mounting bracket by first making contact 

with the lip in the upper side of the base and the metal mounting bracket. When the base has been snapped onto the bracket, take 

the two (2) 6-32 x 1/2” pan head screws that orginally came installed on the base and screw them back into the two holes on the 

underside of the base to secure the base to the metal mounting bracket.

Connect switch box wires to clock harness - 

Take the wiring harness supplied with the clock and make all necessary 

connections between the wiring harness and the switch box wires using wire nuts. Perform this task for both clocks. If using IP 

clocks, wiring will not be supplied with the clocks - the installer will be responsible for supplying all Ethernet wiring.

Plug and secure wiring - 

Loosen and slip excess wiring through provided wire clamp (comes attached to each housing) and 

tighten the clamp. After securing excess wiring, plug the jack at the end of the wiring harness into the appropriate jack on the back 

of the display board. Perform this task for both clocks.

Mount display board to housing - 

 Using the four (4) self tapping, 6-19 x 1/2" flat head screws supplied in the assembly kit, 

take the display board and screw it to the front side of the clock housing (4 screws per clock).

Snap on filter - 

Take the red filter bezel and snap it on to the front side of each clock housing.

Snap on frame - 

Take the gray frame and snap it on to the front side of each clock housing.

Summary of Contents for V-D2425

Page 1: ...V D2425 and V D2440 Digital Clock Installation Manual V1 03 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com...

Page 2: ...ting 10 V D2425 and V D2440 Wired Clock Table of Contents 2 Flush Mount Installation 3 Surface Wall Mount Installation 4 Metal Double Mount Installation 5 Plastic Surface Wall Mount Installation 6 Pla...

Page 3: ...Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated tra...

Page 4: ...lcom com 4 Flush Mount Angled View Front View Side View H 4 65 W 10 3 Flush Mount Picture 2 5 Figure 1 Front view Flush Mount Angled View Front View Side View Flush Mount Picture 4 0 Figure 2 D3 28 D4...

Page 5: ...nut included in the kit 3 Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the tra...

Page 6: ...7 Insert the support bracket onto the hanger mounting rod 8 Screw the two 2 nuts included in the kit onto hanger mounting rod and secure the clock base to wall 9 Connect the ground wire into the doubl...

Page 7: ...Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com 7 Plastic Surface Wall Mount Installation e w q r t y Installation Instructions...

Page 8: ...the inside of the housing and the four holes in the gang box Note If using a metal gang box a ground must be provided to the gang box w Feed Wiring Into the Housing Take the wire coming from the insi...

Page 9: ...Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com 9 Installation Instructions Plastic Double Mount Installation q t i a y r w w e u o...

Page 10: ...les on the mounting pole where the wiring will be routed the installer will chose which hole at the end of the pole to use based on how far they want the clock to sit from the wall Screw from the insi...

Page 11: ...e wiring harness and the switch box wires using wire nuts Perform this task for both clocks If using IP clocks wiring will not be supplied with the clocks the installer will be responsible for supplyi...

Page 12: ...9 540 563 2000 P 540 362 9800 F www valcom com 12 Wiring Information Wiring and Jumper Settings Jumper Number On Off JP1 12 24 Hour Mode 12 Hour Mode 24 Hour Mode JP2 Brightness Brightest Bright JP3 L...

Page 13: ...nication Wiring Information 18 19 110V EU 240V White Black White Black V D2425 or V D2440 V A2412 or V A2416 V CCU V C6124P 24 volt outputs 24 VDC IN DATA IN 19 18 2 W ire Digital Output to Clocks V C...

Page 14: ...r wires NOTE If you fail to follow instructions a and b listed above the fuses can be blown Clock is only displaying dashes What do I do This means that the clock is receiving power but not receiving...

Page 15: ...aster clock and resets itself to display the correct time This occurs within seconds of power up so no battery backup is required for a timekeeping base within the individual clocks Since the clock do...

Page 16: ...nt and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Complianc...