Status Indicator Lights 

The VE8004A/VE8004AR has 3 status indication 
lights on the front panel: 

 

STATUS: 

Illuminates at regular intervals during 

normal operation.  On steady indicates unit is in 
reset mode. 
 
The network jack provides two LED indicators:    

 

Green LED:

 (Link) Indicates Ethernet connection 

when illuminated.   

 

Yellow LED:

 (Activity) Indicator flashes to indicate 

network activity. 

 

Signal Connections 

The VE8004A/VE8004AR has five signal 
connectors on the rear panel: 

 

  1 RCA jack for AUX audio input 

  4 RJ-45 connectors for signal  connections for 

each networked channel 

 

AUX Input

: Local audio may be input via the 

rear panel RCA jack.  Nominal input impedance 
is 600 Ohms.  Connect any compatible audio 
source using an RCA patch cable.  Audio 
supplied through the rear panel RCA jack is 
transformer coupled to both Audio Out channels 
when Audio Out is idle.  This is typically

  

used for background music.

 

 

 

 

 

 

 
 
 

Rear View 

 
Networked Channels: 

Access to the networked 

audio output, audio input, contact closure input and 
relay closure output is provided via four rear panel 
RJ-45 connectors.  Provided with the 
VE8004A/VE8004AR are four RJ-45 patch cables 
and four VM-186 RJ-45 Connectors.  Signals 
connections are made by connecting one end of a 
patch cable to the VE8004A/VE8004AR and the 
other to the VM-186 connector.  Access to the 
signals is via screw terminal connections or 110-
style punchdown block on the VM-186 (see Figure 
2).  Signals are present on pairs of pins as shown 
in Figure 2.

 
 
 
 
 
 
 
 
 
 
 

 
 

Figure 2.  VM-186 RJ-45 Connector 

 

Setup 

Information specific to your application will need 
to be programmed into the VE8004A/VE8004AR 
using a computer.  The PC used for programming 
should be connected to the same subnet as the 
VE8004A/VE8004AR.  Setup will be done using 
the IP Solutions Setup Tool. Download the latest 
version of the free IP Solutions Setup Tool from 
Valcom website at www.valcom.com/vipsetuptool. 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections.  If a spare unit is available, substitute 
a spare unit for the suspected defective unit. 

 

Assistance in troubleshooting is available from the 
factory. Call (877) 427-2166 and ask for Valcom 
Engineered Solutions Technical Support, or visit 
our website at www.ValcomES.com. 

Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person and the nature of 
the problem. Send the unit to: 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056  

 
 
 
 
 
 
 
 
 
 
 
 