INTRODUCTION 

The VE8024A/VE8024AR Quad Enhanced 
Networked Trunk Port allows most loop start 
station ports to be connected to a managed        
IP-based LAN/WAN.  SIP connectivity allows the 
VE8024A/VE8024AR to act as a gateway device 
between a SIP telephone system and the loop start 
Valcom paging systems. 
The VE8024A is designed for wall or table 
placement. The VE8024A

R is designed for 19” 

rack mounting (1U). 
 

SPECIFICATIONS 

Access Methods 

  PBX, FXS Port 

  SIP 

 

Features 

  RJ45 for network connection 

  4 RJ11 FXO connections 

  4 RJ11 failover telephone connections 

  Decode Caller ID signals 

   Front panel activity LED 

  Network activity LEDs  

  2.5mm jack for optional DC power  

  Power over Ethernet (PoE) 802.3af compatible 

 

Dimensions/Weight (VE8024A) 

  1.38 H x 6.13" W x 5.25" D  

     (3.50cm H x 15.6cm W x 13.33cm D) 

  Weight: 1.25 lbs.  (0.57 kg)

 

 

Dimensions/Weight (VE8024AR) 

   

1 Standard 19” Rack Unit 

   1.75 H x 16.50" W x 5.25" D  

      (4.45cm H x 41.91cm W x 13.33cm D) 

   Weight:   5.10 lbs.  (2.32 kg) 

 

Nominal Specifications

 

Input Impedance: 

600 Ohms 

Input Level: 

-10dBm 

Output Impedance: 

600 Ohms 

Output Level: 

- 10dBm nominal 

 
 

 
 

VE8024A 

 
 

 
 

VE8024AR 

 

Nominal Power Requirements

 

Via back panel barrel connector: 

Voltage:   

 

 

 

 24VDC  

Current: 

 

 

 

 325mA  

Via 802.3af PoE Ethernet Switch: 

802.3af: 

 

 

 

Class 3 

 

Environment

 

Temperature: 

                                 0 to +40° C 

Humidity:     

          0 to 85% non-precipitating 

 
These  products  are  intended  for  use  with  a  UL 
Listed  power  source  marked  “Class  2”  or  “LPS” 
rated 24VDC, or 48VDC (PoE). 
PoE  and  all  interconnected  ITE  are  intended  for 
intra-building

 

Precautionary Designations 

 

WARNING

To Reduce The Risk Of Fire Or 

Electric Shock.  Do Not Expose This 
Apparatus To Rain Or Moisture.

 

 

AVERTISSEMENT: Afin de réduire les 
risques d'incendie ou de décharge 
électrique, évitez d'exposer le système à la 
pluie ou à l'humidité. 

 

Apparatus shall not be exposed to 
dripping or splashing and no objects  

  

filled with liquids, such as vases, shall be 
placed on the apparatus. 

 

L’appareil ne doit pas être exposé à des 
égouttements et éclaboussures et  
aucun Objet Rempli de liquide, comme 
vase, ne doit être placé sur l’appareil. 

 
 

Reviews: