3
947565
Figure 3. Mounting to Wall stud
Power Connections
The only method of powering a VIP-148AL-SA
Network Interface is via a Power over Ethernet
(PoE) switch or power injector meeting the
802.3af specification. Make all required signal
connections before connecting to Ethernet switch
or power injector meeting the 802.3af
specification.
Network Connection
The VIP-148AL-SA Network Interface has one
RJ-45 Ethernet network connector and one RJ-45
horn connector.
Use a standard Ethernet patch cable to connect
the VIP-148AL-SA to an Ethernet switch.
Signal Connections
Audio output connection is made from the Signal
Output. The RJ-45 connector on the horn is
connected directly to the RJ-45 Signal Output
socket on the Network Interface. If additional
length is required, any standard T568B extension
may be used. See Figure 4
.
If desired, a normally-open call button may be
connected to the Blue, White/Blue pair of the
horn RJ-45 connector. The VM-186 RJ-45
connector provides easy access to these
connections.
Status Indicator Lights
The VIP-148AL-SA has 2 status indication lights
located on network jack:
Green LED:
(
Link) Indicates Ethernet
connection when illuminated.
Yellow LED:
(Activity) Indicator flashes to
indicate network activity.
Setup
The VIP-148AL-SA will automatically acquire an
IP address (using DHCP) and connect to the
Syn-Apps Revolution server when connected to
the network and powered up. Information specific
to your application will need to be programmed
into the Revolution server. Refer to the Syn-Apps
documentation for further information. Additional
setup, if necessary, will be done using the
Valcom IP Solutions Setup Tool. The IP
Solutions Setup Tool is available for download on
the Valcom website at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
Assistance in troubleshooting is available from
the factory when problems are encountered.
Call (540) 563-2000 and press 1 for Technical
Support or visit our website at
http://www.valcom.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number, contact
person and the nature of the problem. Send the
unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
WARRANTY
Warranty information may be found on our
website at www.valcom.com/warranty.