background image

 

 

                                           

CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

INSTALLATION 

FCC Information 

This equipment has been tested and found to 
comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable 
protection against harmful interference when 
the equipment is operated in a commercial 
environment.  This equipment generates, uses 
and can radiate radio frequency energy and if 
not installed and used in accordance with the 
instruction manual, may cause harmful 
interference to radio communications.  
Operation of this equipment in a residential area 
may cause harmful interference in which case 
the user will be required to correct the 
interference at his own expense.  

 

Precautionary Designations 

 

 

 
 
 
 
 
 
 

 
 
 

 

 

Mounting (VIP-LLE)

 

The VIP-LLE Network Extender is designed for wall 
or shelf mounting and must be within 300 feet of the 
network switch. 
 

Shelf: 

Provided with the VIP-LLE Network Extender 

are four rubber stick on pads.  Peel pads off their 
carrier backing and place at the four corners of the 
bottom of the unit. 

 
Wall: 

Using the brackets and wood screws 

provided, secure the VIP-LLE Network Extender 
to the wall. 

 

Mounting (horn) 

FLUSH MOUNT 

The cardboard packing material in which the horn is 
shipped also serves as the template for flush 
mounting.  Using the template, draw the speaker 
outline on the wall to be cut.  Make appropriate 
wiring connections and test the speaker for 

operation.  Using appropriate mounting screws 
(not furnished) drill and mount the flange as 
shown. 
 

UNIVERSAL BRACKET 

Loosen or separate the universal bracket leaves 
by loosening or removing the handle and 
hardware.  Using the back leaf as a template, 
mark the wall through the mounting holes. Drill 
and mount to the wall using appropriate screws 
(not furnished) or mount directly to a junction box. 
Mount the T-bracket to the back of the horn as 
shown using the (2) ½ inch screws provided. 
 

“C” CLAMP FOR “I” BEAM MOUNTING 

A “C” clamp is provided with the horn to allow 
mounting to a beam.  Attach the “C” clamp to the 
back of the horn as shown using the (2) ½ inch 
screws provided.  Place the bolt through the hole 
in the bottom of the base to secure the “C” clamp 
to the beam.  It is suggested that the horn be 
mounted to the underside of the “I” beam to 
provide maximum positioning adjustments. 
 

Interconnections 

The only method of powering a VIP-480L IP 
Paging Horn is via a Power over Ethernet (PoE) 
switch or power injector meeting the 802.3af 
specification.  

 

Make all required signal connections before 
connecting to Ethernet switch or power injector 
meeting the 802.3af specification.  Power is 
supplied to the horn assembly via the 
VIP-LLE Network Extender. 

 

Network Connection  

As shown in Figure 1, the LLE Network Extender 
has one RJ-45 network connector on the front 
panel.  Use  a standard Ethernet patch cable to 
connect the NETWORK  connector of the LLE 
Network Extender to a 802.3af compliant PoE port 
(300 feet maximum distance).  
 

Signal Connections  

As shown in Figure 1 and 2, audio output 
connections are made on the rear panel of the 
LLE Network Extender.  Versions of the LLE 
Network Extender with the color-coded, 8-pin 
screw connector will connect standard CAT-5 
twisted-pair cable from the rear panel color coded 
connector of the LLE Network Extender to the 
supplied VM-186 RJ-45 connector (900 feet 
maximum distance).  Connect RJ-45 connector   
of horn to VM-186 RJ-45 socket.