background image

 

 

3

 

947818

 

                            

VM-186

RJ45

BLUE

ORANGE

GREEN

BROWN

BROWN

BLUE

N/O RELAY OUTPUT

AUDIO INPUT

CONTACT CLOSURE INPUT

AUDIO OUTPUT

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

 
Network Connection

 

The VIP-802A has one RJ-45 network connector 
on the front panel. 

 

Use a standard Ethernet patch cable to connect 
the VIP-802A to an Ethernet switch. 
 
 

Status Indicator Lights 

The VIP-802A has 3 status indication lights on the 
front panel: 

 

STATUS: 

Illuminates at regular intervals during 

normal operation.  On steady indicates unit is in 
reset mode.   
 
The network jack provides two LED indicators: 

 
Green LED:

 (Link) Indicates Ethernet connection 

when illuminated. 

 
Yellow LED:

 (Activity) Indicator flashes to indicate 

network activity. 

 

Signal Connections 

The VIP-802A has 3 signal connectors on the rear 
panel: 

 

  1 RCA jack for AUX audio input 

  2 RJ-45 connectors for signal connections for 

each networked channel 

 

AUX Input

: Local audio may be input via the rear 

panel RCA jack. Nominal input impedance is 600 
Ohms. Connect any compatible audio source using 
an RCA patch cable. Audio supplied through the 
rear panel RCA jack is transformer coupled to 
Audio Out channels when Audio Out is idle. This is 
typically

 

used for background music and can be 

enabled or disabled for each channel.

 

 

 

 

 

 

 
 
 

Rear View 

 
Networked Channels

: Access to the networked 

audio output, audio input, contact closure input and 
relay closure output is provided via two rear panel 
RJ-45 connectors.  Provided with the VIP-802A are 
two RJ-45 patch cables and two VM-186 RJ-45 
Connectors.  Signal connections are made by 
connecting one end of a patch cable to the VIP-
802A, Port 1 or Port 2, and the other end of the 
patch cable to the VM-186 connector.  Access to 

the signals is via screw connections or 110-style 
punch down block connection on the VM-186 (see 
Figure 3).  Signals are present on pairs of pins, as 
shown in the following chart: 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3. VM-186 RJ-45 Connector 

 

Setup 

Information specific to your application will need to 
be programmed into the VIP-802A using a 
computer. The PC used for programming should 
be connected to the same subnet as the VIP-802A. 
Setup will be done using the IP Solutions Setup 
Tool.  Download the latest version of the free IP 
Solutions Setup Tool from Valcom web site at 
www.valcom.com/vipsetuptool. 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections.  Check voltages for proper polarity to 
the one-way amplified speakers.  If a spare unit is 
available, substitute a spare unit for the suspected 
defective unit. 
 
Assistance in troubleshooting is available from the 
factory. Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
support@valcom.com.  

When requesting assistance, you should include 
all available information.  General information and 
troubleshooting procedures are available on the 
Valcom website at www.valcom.com. 

Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person and the nature of 
the problem. Send the unit to: 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056  

 