Page 49
Installation and Operation Manual - FP18 Dallaire
ENGLISH
9.5.2 Offset Support
This support is used above a chimney offset. When the offset of the
chimney pass through a wall, this support can be installed on the wall to
support the chimney.
9.5.3 Offset chimney installation
It is permitted to offset the chimney when installing provided that the following measures are
always respected. For a
left or right deviation (A)
there must always be a distance of
11"
between
the chimney and combustible materials. For a
forward deviation (C)
there must always be a
distance of
4 3/4"
between chimney and combustible material and
rear deflection (B
), there
should be a 2" distance between the chimney and combustible materials. It is permitted to offset
the chimney when installing the two elbows directly on the anchor plate.
For example, for the next installation, the chimney cannot
be closer to the combustible materials than the
value (A)
.
Therefore, the enclosure should be 11 inches from the
chimney.