52
7.5
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a non-combustible floor or on the ground, well away from combustible
materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed they should be retained in the closed container until all cinders have thoroughly cooled.
7.6
Refractory Panels Replacement
Do not use the fireplace with a broken or missing refractory panel.
Here are the steps to replace the refractory panels of your FP-7 LM Antoinette fireplace:
1. Remove the Andirons (VA7070) by unscrewing the anchoring bolts. Figure 42.1
2. Remove the bottom refractory panel (22198). Figure 42.2
3. Unscrew the refractory panel retainers (2x: 1 left and 1 right) (PL64601). Figure 42.3
4. Remove the left and right side refractory panels (22195 and 22194). Figure 42.4
5. Remove the back refractory panels (22196 and 22197). Figure 42.5
6. To reinstall the replacement refractory panels, just follow the steps in reverse.
Figure 41: Replacing Antoinette refractory panels