Zero Power Output
Possible Source
of the Error
Test
Solution
Not enough wind
Test wind speed
Wait for higher wind speeds.
NOTE: The Hyland 920 should begin
producing power at wind speeds greater
than 3.5 m/s.
Turbine is switched
Short
Brake is Switched
ON
Check SHORT/RUN switch and
BRAKE/RUN switch on the
controller
Switch both switches to RUN on the
controller
Fault in electrical
circuit
• Switch BRAKE/RUN and
SHORT/RUN switches on
the controller to the BRAKE
and SHORT positions
respectively.
• Contract qualified
electrician to check
electrical circuit
Repair by authorised personnel
Turbine spins in
windy conditions
but makes no power
• Check continuity between
phases at controller plug
• Check battery state of
charge
• Check charge light on
controller if red there is a
fault
• If there is an open circuit phase check
plug and connections.
• If full the controller will divert power to
the dump resistor
• Contact sales@valen.com.au
12