for personal safety:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE
FROM THE POWER CORD.
EARTHING
CONNECTION
Connect the cold water supply hose to a threaded 3/4 (inch) connector and make sure
that it is fastened tightly in place.
If the water pipes are new or have not been used for an extended period of time , let the
water run to make sure that the water is clear. This precaution is needed to avoid the
risk of the water in let to be blocked and damage the a ppliance.
Insert the drain hose into a dra in pi pe with a minimum diameter o f 4 cm, o r let it run into the sink, making sure to
avoid bendin g or crimping. Use the special plastic support th at comes with the appliance. The f ree end of the hose
must be at a height between 40 and 100 cm and must not be immersed in w ater.
Improper connection of the equipment earthing conductor can result in the risk of an
electric shock.
Check with a qualified electrician or service representative if you are in doubt whether the
appliance is properly earthed.
Do not modify the plug provided with the appliance. If the plug does not fit properly to the
outlet, please have a qualified electrician to install a proper outlet.
Please close the hydrant after using.
14
FRONT VIEW
Inlet pipe connector Drain pipe connector
P O W E R O U T L E T
SINK
DISHWASHER
Min 100mm
Summary of Contents for EDPR60SS
Page 1: ...EDPR60SS EDPR60WH...