2.
Technical data
Model:
V200 V200T
V250 V250T V2200 V2200T V400 V400T
V600
Power
[kW]
7.2 11 7.2 11 14.4 22 14.4 22 21.6
Connection
3P+
E
[A]
10 16 10 16 20 32 20 32 32
Frequency
[Hz]
50 - 60
50 - 60
50 - 60
50 - 60
50 - 60
50 - 60
50-60
50-60
50-60
Security circuit cable SOLAS
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
4x1.5
Power
connecting
cable
4x1.5 4x1.5 4x1.5 4x1.5 4x2.5 4x4 4x2.5 4x4 4x4
Capacity in litres
7-9
7-9
8-10
8-10
2x 7-9
2x 7-9
18-20
18-20
25-28
Working
thermostat
1 1 1 1 2 2 1 1 1
Security
thermostat
1 1 1 1 2 2 2 2 3
Timer
1 1 1 1 2 2 1 1 1
Chips fried kg / h
19-23
26-32
19-23
26-32
38-46
52-64
38-46
52-64
57-68
Protective system
IP X4
IP X4
IP X4
IP X4
IP X4
IP X4
IP X4
IP X4
IP X4
Weight
[kg]
34 35 35 36 52 53 49 50 69
Dimensions [cm]
20x58x85
20x58x85 25x58x85 25x58x85 40x58x85
40x58x85
40X58X85
40X58X85 60X58X85
3. Installation
Erect fryer, to level rotate the setscrews underneath the front feet.
The fryer must not stand on combustible surfaces. Local safety regulations must be complied with.
N.B.: The slimline fryers V200 and V200T, as well as V250 and V250T, must not be freely erected (risk of
tipping over). They must be installed between 2 units of furniture, or they must be supported on the sides.
3.1 Electrical connection for Valentine Fryers in SOLAS version
Only experts may connect and commission the fryers.
Your mains data (voltage, current, fuse protection) must conform to the data on the fryer rating plate (The
rating plate is mounted on the inside of the door (Figs. 1 to 3 = D).
Valentine Marine Fryers in SOLAS version are equipped with 2 cables:
a)
Security circuit cable
Terminals 1 2 3 4 (see Circuit diagram, page 12)
Terminals 1 + 2 need power from main galley to activate contactor K4. Circuit passes all security thermostats.
Terminals 3 + 4 potential free contact in series over all security thermostats (for ex.: to connect
alarms, flashing lights, horns, etc. on the main galley).
b)
Power connecting cable
Terminals L1 L2 L3 (see Circuit diagram, page 12)
The electrical connection must conform to local regulations, essentially as follows :
- Fitting a mains plug on the connecting cable. Earth conductor = yellow/green, Phase sequence is immaterial.
- Any fixed connection must be made via a mains switch with all-pole isolation (min. contact distance 3 mm.).
- Before connection is made to the mains, check that the main switch "E" of the fryer is in the "0" position.
Never heat without oil !
3.2 Installation examples
A considerable amount of steam is generated when preparing chips. A good steam extractor is strongly
recommended.
3.2.1 Installation example I (Fig. 1)
Wall socket [F] resistant to dripping water IP X2 or water spray IP X4
3.2.2 Installation example II (Fig. 2)
Fryer free-standing or next to cooking range. Connection column [H] with socket IP X2 or IP X4
3.2.3 Installation example III (Fig. 3)
Connection box [J] with 3P+N isolating switch arranged above fryer. Cable permanently connected. Because of
the considerable steam generated the box must be watertight IP X5.
Date of creation: 15.01.98 by W/mm
Date of modification: 10.09.01 by W/fd
File:
Fabrique SA
Doc. N°
A2000B SO
Page No.:
4