OPERATING INSTRUCTION
Parameters
Parameter Name
Description
Value
Interval
Standard
Value
P60
NTC 3 Ice Sensor Lower Floor
Type of sensor used:
• 10K (0).
• 3K (1).
• 30K (2).
• ON/OFF (3).
• Disable (4).
0 - 4
3
P61
NTC 4 Ice Sensor Lower Floor
Type of sensor used:
• 10K (0).
• 3K (1).
• 30K (2).
• ON/OFF (3).
• Disable (4).
0 - 4
4
P62
Maximum difference between Floor
Set-point Upper and Lower.
Maximum allowed difference between the Upper and Lower Floor Set-point.
0 - 5
5
P63
Evaporator Fans
Type of Fan used:
• Brush fan (0).
• Electric fan (1).
0 - 1
1
P64
Condenser Fans
Type of Fan used:
• Brush fan (0).
• Electric fan (1).
0 - 1
0
P65
ECU configuration selection.
Configuration being used:
• Parameter disabled (0).
• Standard (1).
• Basic DD (2).
• Basic DD without heating (3).
• Basic SD (4).
• Basic SD without heating (5).
• Cabriolet (6).
0 - 6
0
P66
Re-Heat
(Window Defroster)
Re-Heat availability:
• 0: not available
• 1: available 8°C
• 2: available 0°C
0 - 2
0
CC 430 P3