406
REVO-E Heat pump
4 Function and functional schematics
4.4.2 Heating and Ventilation Mode Ready for
cooling
Requirements:
–
Clamp 30 / 15 active
–
Vehicle hybrid system active
–
HV Mode required by BEA body
Preconditions for Cooling Mode filled shortly before or
after this, however cool request not sent by BEA body.
System works primarily in Heating / Ventilation Mode.
Fig. 404 Heating and Ventilation Mode Ready for Cooling
Double radial blower
Double radial blower
Fresh air
flaps
Sensor
pass. comp.
temperature
Sensor
blow-out
temperature
I/O-A module
Vehicle
Requirement
open / close
Heating valve
actuator
Fresh air
flaps
actuator
Analog input
HVIL 1 voltage
Analog input
HVIL 2 voltage
CAN interface
vehicle
SC620
4
5
1
2
3
6
7
24V
for hot water
heat exchanger
ADA
1 Solenoid valve
2 Solenoid valve HGA / actu-
ator
(in 11123865_only)
3 Suction pressure sensor
4 High pressure safety switch
5 Low pressure safety switch
(
not in 11123865_
)
6 4-way reversing valve
7 High pressure sensor
Summary of Contents for REVO-E
Page 1: ...Rev 06 2019 Id No 11123006A REVO E Heat pump Volvo Workshop Manual AIR CONDITIONING...
Page 51: ...605 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 4...
Page 52: ...606 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 5...
Page 55: ...609 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 1...
Page 56: ...610 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 2...
Page 57: ...611 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 3...
Page 59: ...613 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 5...
Page 87: ...memos...