REVO-E Heat pump
4 Function and functional schematics
Task of the SC620:
–
Control the speed of the double radial blowers / axial
fans
–
Activation and speed setting of the compressor (via
frequency converter)
In Cooling mode Mode, the BEA body is not able to influ-
ence the speed of the double radial blowers.
The value of the interior temperature to be reached is
given by the difference of the external temperature and
the
∆
T required by the BEA body.
Example of
∆
T – 7 Kelvin
T
passenger cabin
= [T
external
(35°C) +
∆
T (7K)]
T
passenger cabin
= 28°C
This value is sent via CAN by the BEA body and is used
as an internal control signal.
The "D_ElAcMaxPowerAllowed" CAN signal (from the
vehicle's power system) specifies the maximum power
consumption of the compressor.
If the cooling requested cannot be implemented (e.g.
malfunction), the system automatically switches to
Heating/ Ventilation Mode.