802
REVO-E Heat pump
8 Removal/ installation of components (high-volt. syst.)
8.4
Frequency converter removal/ installation
8.4.1 Remove the frequency converter
1. Prepare to remove the frequency converter
• Loosen the mount for the grounding cable (4).
• Loosen the diagnostic cable (3).
• Loosen the with sealing wax secured captive cover
screws (1).
• Lift the cover, remove the grounding cable.
2. Disconnect the electrical connections of the frequency
converter.
• Check the connections L1 and L3 (
) are
voltage free using a suitable voltage tester (CAT
IV).
• Remove power supply from the terminal strip.
• Remove the HVIL plug.
Fig. 801
1
2
1 Cover of the frequency converter
2 Torx screws (6)
Fig. 802
1 Frequency converter Cover screws (4x)
2 400V AC cable
3 Diagnostic cable
4 Mount for grounding cable
5 Screws (4x) with centering cone
6 600V DC cable for power supply
See torque table
1
2
3
5
6
4
Summary of Contents for REVO-E
Page 1: ...Rev 06 2019 Id No 11123006A REVO E Heat pump Volvo Workshop Manual AIR CONDITIONING...
Page 51: ...605 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 4...
Page 52: ...606 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 5...
Page 55: ...609 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 1...
Page 56: ...610 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 2...
Page 57: ...611 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 3...
Page 59: ...613 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 5...
Page 87: ...memos...