background image

BUS BODY ELECTRONICS

 

 

 

2  Use 

2.1  Activation/deactivation 

2.1.1  Activation 

Press 

 

button

 

  Sets the last configured temperature; Auto mode off 

(Figure 4). 

2.1.2  Deactivation 

Press 

 button

 

  Display deactivated. 

Press 

 button for 2 seconds until OFF appears 

  System deactivated. 

2.2  Auto mode 

 

2.2.1  Activation 

Press 

 button if Auto mode is off

 

  Mode is on - corresponding status light and function 

symbol light up on the display (Figure 6). 

 

 

 

Note 

Auto  mode  can  be  turned  on  only  if  the  motor  has  been 

started. 

 

Note 

If Auto mode is on, the system automatically turns on Cool-

ing mode 

 and Heating mode 

 (if available) as needed 

(Figures  7  and  8).  The  air-conditioning  system  and  heater 

are permanently set to dehumidify. 

Figure 6 - SC600 Auto mode activated

 

 

 

Figure 7 - SC600 Auto mode activated, 
Cooling mode 

 

Figure 4 - SC600 start display 

Figure 5 - SC600 deactivation

 

Figure 8 - SC600 Auto mode activated, 
Heating mode 

 

Summary of Contents for SC600 Australien

Page 1: ...Rev 21 11 2018 Id No DOK30605 BUS BODY ELECTRONICS SC600 AUSTRALIEN Operating instructions Busdriver...

Page 2: ...2 Use 6 2 1 Activation deactivation 6 2 1 1 Activation 6 2 1 2 Deactivation 6 2 2 Auto mode 6 2 2 1 Activation 6 2 2 2 Deactivation 7 2 3 Configuring the blowers manually 7 2 3 1 Activating the contro...

Page 3: ...SC600 Auto mode activated Cooling mode 6 Figure 8 SC600 Auto mode activated Heating mode 6 Figure 9 SC600 Auto mode deactivated 7 Figure 10 SC600 setting the blower level manually 7 Figure 11 SC600 r...

Page 4: ...This control panel allows the driver to control the roof top air conditioning system that has ven tilation cooling and heating functions for the roof Additionally this control panel can also be used t...

Page 5: ...isplay 1 Display 2 On off button 3 UP button 4 DOWN button 5 Function status light 6 Blower button 7 Fresh air recirculating air button 8 Auto button A Desired value display room temperature B Blower...

Page 6: ...unctions and infor mation summa rized under point 2 as well as Error mode The normal operat ing display includes all of the elements provided here in the example Error detection mode Mode to display a...

Page 7: ...corresponding status light and function symbol light up on the display Figure 6 Note Auto mode can be turned on only if the motor has been started Note If Auto mode is on the system automatically tur...

Page 8: ...3 2 Setting blower level The blower can be set in level increments of 0 blower speed 0 to 10 blower speed 100 Press button Blower level 1 Press button Blower level 1 Note When Auto mode is deactivate...

Page 9: ...tes the system turns off the manual recirculating air function The system then controls the fresh air valves automatically Pressing the button again within 10 minutes will de activate the manual recir...

Page 10: ...rror detection Scroll through the error codes with or Reset the counter with after resetting the coun ter shower the value 1 if the error persists 2 6 1 3 Ending Press and buttons for 2 seconds Normal...

Page 11: ...rness de fective F020 Room temperature sen sor Defective sensor Wiring harness de fective F021 Environmental tempera ture sensor Defective sensor Wiring harness de fective F022 Ice sensor Icing Temper...

Page 12: ...Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 82198 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com...

Reviews: