505
Thermo AC/DC
5 Troubleshooting
5.5
Error symptom „Overheating / the temperature limiter has tripped“
5.6
Error symptom „Over heating“
The upper switching threshold is exceeded, but the tem-
perature limiter does not trip.
Is the circulating pump switched on
and works properly?
Turn the circulating pump on, check
its function and the direction of rota-
tion. Replace if necessary..
NO
YES
Replace temperature limiter.
Check the temperature limiter (see
). Does the temperature
limiter function properly?
Does an adequate cooling and
coolant flow exist?
Are all shut-off devices open?
Is the cooling system tight, comple-
tely filled and bled?
Is the coolant sufficiently cold-re-
sistant?
Eliminate the fault.
Replace control thermostat.
NO
YES
Check the control circuit on the
heater side for a short circuit.
Check the control thermostat (see
). Does the control ther-
mostat function properly?
Summary of Contents for Thermo AC 070