506
Thermo AC/DC
5 Troubleshooting
5.7
Error symptom “ISO value too low (unacceptable)“
Perform a visual inspection whether cables are damaged or squashed and rest against the housing (metal parts).
The insulation resistance must be measured at a test voltage of 1000V DC.
Wires undamaged and free?
Replace damaged or pinched
cables.
Contact the vehicle manufacturer.
NO
YES
Vehicle-side insulation value
sufficient?
Replace the HV wiring harness
(see
).
Insulation value up to the load con-
tactor sufficient?
Contact Valeo customer service
Insulation value after the load con-
tactor sufficient?
Contact Valeo customer service