28
Annex
Thermo DC 200
Technische Daten
Bild 14: Hook-up schematic
L1
L2
L1 L2
35A
Valeo Thermo DC
Circuit breaker
486V DC
after electricity
IMD 0.5 M
Ω
meter
Overcurrent protec-
tion device acc. to
table Technical Data
DC 24V 0Hz
Heater (electrical system)
Thermo DC200 (486V)
Ident. no.
11126153_
Nominal heating flow
kW
20
Nominal voltage
VDC
486
Frequency Hz
--
Nominal current
A
41,7
Rated current at 400V DC
A
34,4
Rated current at 486V DC
A
41,7
Rated current at 540V DC
A
46,4
Rated current at 600V DC
A
51,5
Type of electrical protection
1000V DC/xxA/10kA
fast-blow
Circuit breaker rating
A
60*
Operating voltage range HV
VDC
0 - 600
Cross section HV supply cable
mm²
10
HV wiring harness at heater side
2ea ferrules 10mm²
Min. cable cross section at
vehicle side
mm²
10
Insulation resistance new device at
1000V
M
Ω
>100
Insulation resistance end of life at
1000V
M
Ω
>50