Hook-up (High voltage)
Thermo H
63
Legend for the hook-up plan:
HV Connection AC
HV Connection DC
LV Connection
Connector*
1-2282265-1
Connector
C10-737974-AFS
Connector
HDSCS 1-1418479-1
Conn. Heater
Cable
Color
Conn. Heater
Cable
Color
Contact
1241380-1
PE
6mm²
GN/YE
HVIL*
0.75mm²
WH
Seal
963530-1
L1
GY
HVIL*
0.75mm²
BN
Connection to heater
Cable
Pin
Color
L2
BK
+
3.5 / 6mm²
BU
Activation signal AC
0.75 mm²
1
BK
L3
BN
-
3.5 / 6mm²
RD
Activation signal DC
2
RD
N
BU
Thermostat feedback
3
BU
Overheat protection feedback
4
WH
HV Connection Pump
Ground
5
BN
Conn. Heater
Cable
Color
HVIL in
6
GN
L1
2.5mm²
BK or BN
HVIL out
7
YE
N
BU
Contactor feedback
8
OG
PE
GN/YE
*) as already installed
Summary of Contents for Thermo H