Thermo H
Technical data
78
Optional Fuel Filter Heater
Diesel part
Thermo H
160
230
300
350
Heating flow (at ambient
temperature of 20°C )
kW
kcal/h
16
13800
23
20000
30
26000
35
30000
Fuel
Diesel
Fuel consumption
kg/h
1.6
2.5
3.0
3.6
Rated voltage
V
24
Operation voltage range
V
20 - 30
Electrical power consumption at
24V
W
50
65
90
120
Max. permitted temperature of
sucked combustion air
°C
+85
CO
2
in exhaust gas at rated voltage
Vol %
9.5 + 1.5
Filter heater
Rated power consumption
W
240
Rated voltage
V
24
Switch-on point
C°
0.5 ± 2.5
Switch-off point
C°
5.5 ± 2.5
Summary of Contents for Thermo H