14
3 - HANDLING INSTRUCTIONS
Running-in operation
Whenever moving parts have been replaced, it is
necessary to run-in both the compressor and the
magnetic clutch.
Compressor running-in
Reassembled compressors must be run-in after
the leak test (p.15).
1. Check that the compressor contains the
specified amount of oil (p.13).
2. Interconnect the suction fitting and the
discharge fitting with the flexible hose.
3. Connect the two connector ports using a
flexible hose
4. Run the compressor at 500r/min for 30
minutes to 60 minutes. This operation may be
performed by an electric motor or the engine
of an automobile.
5. Replace the oil.
6. Repeat the leak test.
CAUTION!
While the compressor is being run-in in step
3 above, check the outside temperature of
the front head. If the temperature exceeds
80°C (176°F), stop the running-in operation.
Resume the operation when the head has
cooled.
Connect the flexible hoses to suction and
discharge port