Charge mode for 12V Wet, Gel and MF batteries (14-120AH)
6V SMALL NORM LED
:
Charge mode for 6V Wet, Gel and MF batteries (1.2-14AH)
6V SMALL COLD/AGM LED
:
Charge Mode for 6V batteries below 3
2℉(0℃)and AGM batteries(1.2-14AH)
12V SMALL NORM LED:
Charge mode for 12V Wet, Gel and MF batteries (1.2-14AH)
12V SMALL COLD/AGM LED
:
Charge Mode for 6V batteries below 3
2℉(0℃)and AGM batteries(1.2-14AH)
◆
Charging Steps:
Step 1: Diagnostics
Checks the battery voltage to make sure battery connections are good and the battery is in a
stable condition before beginning the charge process.
Step 2: Recovery
Initializes the Recovery process, if needed, for deeply discharged or sulfated (desolations)
batteries by pulsing small amounts of current.
Step 3: Soft Start
Begins bulk charging process with a gentle (soft) charge.
Step 4-5: Bulk
The bulk charging process continues using both a High Rate and Medium Rate charge and
returns 80% of battery capacity, indicated by the 25%, 50%, 75%CHARGE LEDS.
Step 6: Absorption
Brings the charge level to 90%,the battery charger will deliver small amounts of current to
provide a safe ,efficient charge and limit battery gassing.
Step 7: Trickle
Battery is fully charged and ready to use, indicated by the 100% Charge LED being a solid
Green. In this step, the battery charger will only deliver enough current to keep the battery full.
if the battery tells the charge that more current is needed, the battery charger will switch to
maintenance.
Step 8: Maintenance