Continuously monitors the battery voltage to determine if a maintenance charge should be
initiated. If the terminal voltage falls below 6.4V
(
6V
)
and 12.8V(12V),the charger will start
the maintenance cycle until voltage reaches 7.2V(6V) and 14.4V(12V) and then discontinues
the charge cycle. The cycle between trickle and maintenance is repeated indefinitely to keep the
battery at full charge, without overcharging. the battery charger can be left connected
indefinitely.
◆
Safety information:
Do not use it for any other purpose.
Do not attempt to charge non rechargeable batteries.
Respected the rating of the fuse, which is indicated on the charger.
In case the power cord is damaged, be sure to stop using it at once in order to avoid any danger.
Do not cover the charger while charging.
Charging should be carried out in a well-ventilated, weather protected facility.
Separate collection required. Do not throw in a domestic dustbin.