- 10 -
Adjust the jet, long or mist, turning the nozzle
ring placed on top of the lance (pos.9).
When the spray intensity drops, use again the
damper rod to recharge the tank.
During use, keep the lance facing forwards and
never against yourself.
Do not spray upwards so that the nebulised liquid
does not end up around your mouth and nose.
If you notice any operating faults, consult the
“Problems, causes and solutions” chapter.
At the end of work and before opening the tank
is crucial to fully discharge the internal pressure
by pulling the knob of the safety valve (pos.10).
After use, activate the pump with clean water,
rinse and empty the tank.
TRANSPORT AND STORAGE
!
!
WARNING! Before transporting or storing
the pump, always download the pressure in-
side the tank by pulling the knob of the safety
valve (pos.10).
To transport the pump, hook the lance to the
support
(pos.2)
with the nozzle facing upwards
and lift the pump using the shoulder belt.
If the pump is transported in a vehicle make sure
it does not overturn.
Before storage clean the pump carefully fol-
lowing the indications in the “maintenance and
cleaning” chapter and leave it to dry with the
tank open and overturned.
Always use the packaging when storing the
appliance; this will protect it from impact, dust
and humidity which can compromise normal
operation.
Store the pump out of reach of children, away
from heat sources, food, animal feed or drinks
and protected from the sun and frost.
MAINTENANCE AND CLEANING
!
!
IMPORTANT! Before any checks or main-
tenance, release the pressure and empty the
tank.
The working life and costs also depend on con-
stant and meticulous maintenance. Take good
care of your appliance and clean it regularly. In
this way its efficiency will be ensured and its
lifespan extended.
OUTSIDE
- Remove dust and drips with a cloth.
- Do not use flammable substances, detergents
or solvents but just a damp cloth and water.
- The plastic parts can easily be damaged by
chemical agents.
INSIDE (at the end of every use)
- Empty the tank and the lance; rinse numerous
times including the pump unit and filter, so as
to remove all remains of the product used.
- Dry thoroughly.
Warning! Any remains of product can compro-
mise subsequent operation; this failure is not
covered by warranty.
PROBLEMS, CAUSES AND SOLUTIONS
PROBLEM
CAUSE
SOLUTION
The nebu-
lised liquid
d o e s n o t
come out of
the lance
Lack of pressure Activate the plunger
rod
Tank empty
Fill the tank
Lance tap closed Activate the lance
lever
Hose bent or ob-
structed. Lance
and nozzle ob-
structed
Check the hose, the
lance and the nozzles
Drops of li-
quid on the
appliance
Connections and
cap not tightened
Tighten all the con-
nections and cap
well. If the problem
persists check the
gaskets and replace
them if necessary
!
!
IMPORTANT! If the appliance still fails to
operate correctly after you have carried out
the above operations, or in the event of faults
other than those described above, take it to
an authorised service centre showing proof
of purchase, and ask for original spare parts.