OMNIA
34
6.2
POWER ON SWITCH
Press button A Figure 6-2 to switch on power, the machine is then ready to execute commands.
6.3
STARTING THE VACUUM PUMP AND SELECTING THE SUCTION ZONES
Suction to the work surface is divided into three
areas, two of which can be enabled or disabled
depending on the "size of the material" to be
processed.
Turning the pump switch (1) Figure 6-2
clockwise will start the vacuum pump. Turning
the switch counter clockwise stops the pump
motor.
The suction of zone 1
Figure 6-3 is always open
and will be activated by the software when
necessary for processing.
The two valves (2,3) Figure 6-2, if open, will ensure that when the software activates suction it is extended to the
corresponding sectors of the table Figure 6-3.
Note:
Switching on the pump does not directly produce suction on the surface as this is controlled via software.
Note:
If the software is set to energy saving mode, the pump will be automatically switched off after a certain period of
inactivity.
6.4
LOADER CONTROLS
On the side of the loader are two selectors and an emergency button.
When the left selector is positioned on the MAN function, the automatic
return selector is enabled which allows the loading surface of the materials to
be processed to be raised (UP) or lowered (Down).
When the manual material loading operations are completed, the left selector
must be returned to the AUTO position in order to allow or resume the
automatic processing cycles.
Figure 6-4
1
1
3
2
A
Figure 6-2
1
1
3
2
2
3
Omnia 100
Omnia 80
Figure 6-3