OMNIA
40
6.7.3
TANGENTIAL TOOL PREPARATION
DANGER:
Use protective gloves is strongly recommended, be very careful as the pressure of the moving
part (2) could cause the blade exit.
To mount or replace the blade holder, proceed as follows:
Note: Depending on the blades being used for the desired processes, the relative dedicated blade holder must be
mounted (blade holder for L100 / L1W blades or blade holder for flat blades T16 / 17).
a)
Loosen the locking set screws (1) and remove the movable blade guard (2) Figure 6-15.
Attention: If a blade holder equipped with a blade is already present on the tangential tool, first proceed with the
disassembly of the latter in order to avoid possible accidental injuries (carry out point (e) and then resume the procedure
from point b).
b)
Loosen the set screw (8) and extract the blade holder (9).
c)
Insert the desired blade holder with the reference pin (10) oriented as shown in the figure and make sure that it is
entered up to the stop.
d)
Tighten the set screw (8).
e)
Loosen the blade cartridge screw (3) and remove the used blade (4) (if present).
f)
insert a new blade (4) until the notch of blade reaches the pin (5), then tighten the screw (3).
g)
Position the blade guard so that the reference pin matches its housing (6), then grab it from the sides (7) and push
it towards the tool.
Attention:
while inserting the blade protection, pay attention the palm of your hand is not positioned in front of the
tool as indicated by the prohibition symbol.
h)
Tighten the locking set screws (1).
To replace a blade, carry out the procedure described above, skipping points b) c) d).
1
2
3
4
6
5
8
10
9
7
7
3
4
5
Blade holder
for T16/17
Blade holder for
L100/L1W
Figure 6-15
Summary of Contents for OMNIA
Page 1: ...OMNIA Instruction and Maintenance Manual...
Page 2: ......
Page 65: ......
Page 66: ...002695 rev 02...