There must not be an extractor fan fitted in the
same room as the appliance as this can cause the
stove to emit fumes and smoke into the room.
Clearances
Minimum clearances for installing in a recess or
fireplace:
A.
350mm
D. 50mm
B.
350mm
E.
450mm
C.
100mm
F.
25mm
Installing in a free standing situation:
Distance to Non Combustible materials.
Distance of
appliance to
wall (A)
Minimum
thickness of
wall (B)
Minimum height
of wall (C)
0mm - 50mm
200mm
Height of
app
300mm OR
1200mm from
the hearth
(take largest
dimension)
51mm - 300mm
75mm
300mm+
No requirement
No requirement
Distances to combustibles may be reduced if
a suitable heatshield or insulation is fitted in
accordance with building regulations.
Combustible Materials
B
Non-Combustible Materials
Combustible Materials
Non-Combustible Materials
A
D
C
E
F
C
A
B
150mm