![background image](http://html2.mh-extra.com/html/valley-comfort-systems/mp80/mp80_installation-and-operation-manual_3232576020.webp)
MP80.PUB Version 1.07 20
FAN LIMIT INSTALLATION
Using the bracket provided, install the fan limit and junction box assembly onto the warm air plenum, above
and to the right of the firebox fuel door, as illustrated in Fig 2. All 120vac wiring must be routed on the
outside of the cabinet surface. Installation of wiring must be by a qualified electrician. See specific add on
type instructions for wiring diagrams that apply. Wire between the junction box and the damper motor should
be routed in the outside channel of the bracket, to the right of the firebox door with clips at each end as
required. Clips must not compress leads tightly against the surface.
DOOR AND LATCH INSTALLATION
Install the firebox door on the frame hinges. Install the door latch catch on
to
the frame mounting bracket, as shown below, using the two 1/4" x 3/4"
carriage bolts provided. Adjust the door latch catch for a snug fit of the
door against the gasket. The door gasket will "seat" after a short time so
the
initial adjustment should be snug. Advise the homeowner to check the fit
of
the door gasket from time to time to ensure a seal all around the firebox
door. A loose fitting door will allow entry of excess air and result in
higher burn rates with less control.
FIG 2
FAN & LIMIT &
ELECTRICAL JUNCTION BOX
MOUNTED TO PLENUM
AS SHOWN USING 2 PLY
MOUNTING BRACKET
3.50 in
3.50 in
Ø0.80 in (3x)
TEMPLATE FOR DRILLING HOLES—CUTOUT LINES