Exclusions and Limitations: 

1. This Warranty does not cover tarnish, discoloration or wear on the plated surfaces   Painted finishes will change 
colour after initial firing and will continue to change through the lifetime of the stove. This is normal occurrence for 

all high temperature coatings. 

2. This Warranty does not cover gasket material or firebrick. 

3. Blaze King strongly recommends installation by a certified installer. Failure to comply may adversely affect 
coverage under the terms of this warranty. This Limited Warranty covers defects in materials and workmanship only 

if the product has been installed in accordance with local building and fire codes; in their absence refer to the 

owner’s manual. If the product is damaged or broken as a result of any alteration, wilful abuse, mishandling, 
accident, neglect, or misuse of the product, the Limited Warranty does not apply. 

4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s 

Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. 
Performance problems due to operator error will not be covered by the Limited Warranty policy. 

5. Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect 

and, therefore, is not covered under this Limited Warranty. 

6. Misuse includes over-firing. Over-firing can be identified later by warped plates and paint pigment being burnt off. 
Over-firing this appliance can cause serious damage and will nullify the Limited Warranty. 

7. The Limited Warranty will cover glass thermal breakage only and will not cover misuse of the stove glass, 

including but not limited to: 
a) Glass that is struck, has surface contaminates or has had harsh or abrasive cleaners used on it. 

b) If the door is slammed or is closed while wood in the firebox is protruding out the stove opening thus striking the 

glass. 
8. This warranty does not cover products made or provided by other manufacturers and used in conjunction with the 

operation of this stove without prior authorization from Blaze King The use of such products may nullify the Limited 

Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King 

dealer before installation. 
9. Blaze King will not be responsible for inadequate performance caused by environmental

 

conditions. 

10. The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or 

spillage caused by environmental conditions. Environmental conditions include but are not limited to nearby trees, 
buildings, roof tops, wind, hills, mountains, inadequate venting or ventilation, excessive offsets, negative air 

pressures or other influences caused by mechanical systems such as furnaces, fans, clothes dryers etc. 

11. The Limited Warranty does not cover damage caused by burning salt-saturated wood, corrosive driftwood, 
chemically treated wood or any fuel not recommended in the Owner’s Manual (use cord wood only). 

The Limited Warranty is void if: 

a) The stove has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. 

b) The stove is subject to submersion in water or prolonged periods of dampness or condensation. 
c) Any damage to the unit, combustion chamber or other components due to water, or weather damage which is the 

result of, but not limited to, improper chimney/venting installation. 

d) Salt air in coastal areas or high humidity can be corrosive to the finish; these environmental conditions can cause 
rusting. Damage caused by salt air or high humidity is not covered by the Limited Warranty. 

12. Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to accident, 

negligence, misuse, improper installation, alteration or adjustment of the manufacturer’s settings of components, 
lack of proper and regular maintenance, alteration, or act of God. 

13. The Limited Warranty does not cover damage caused to the stove while in transit. If this occurs, do not operate 

the stove and contact your courier and/or dealer. 

14. The Limited Warranty does not extend to or include paint, door or glass gaskets or firebricks damage caused by 
normal wear and tear, such as paint discoloration or chipping, worn or torn gaskets, chipped or cracked firebrick, etc. 

15. The Limited Warranty does not include damage to the unit caused by abuse, improper installation, or 

modification of the unit. 
16. Damage to plated surfaces caused by fingerprints, scratches, melted items, or other external scores and residues 

left on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty. 

17. Blaze King is free of liability for any damages caused by the stove, as well as inconvenience expenses and 
materials. The Limited Warranty does not cover incidental or consequential damages. 

18. The Limited Warranty does not cover any loss or damage incurred by the use or removal of any component or 

apparatus to or from the Blaze King stove without the express written permission of Blaze King and bearing a Blaze 

King label of approval. 
19. Any statement or representation of Blaze King Products and their performance contained in Blaze King 

advertising, packaging literature, or printed material is not part of the Limited Warranty. 

20. The Limited Warranty is automatically voided if the stove’s serial number has been removed or altered in any 
way. If the stove is used for commercial purposes, it is excluded from the Limited Warranty. 

 

Summary of Contents for MP80

Page 1: ...50 493 7444 www blazeking com Email sales blazeking com READ THOROUGHLY AND COMPLY WITH ALL LOCAL CODES AND REGULATIONS MP80 SOLID FUEL FURNACE FOR USE AS AN ADD ON TO OIL GAS OR ELECTRIC FURNACE OR A...

Page 2: ...MP80 PUB Version 1 07 2...

Page 3: ...UDED 14 OPTIONAL EQUIPTMENT 14 INSTALLATION OPTIONS 14 TYPICAL INSTALLATION DIAGRAMS 15 CLEARANCES 16 ALTERNATE FURNACE LOCATIONS 16 PRESSURE LOSS 17 COMBUSTION AIR 17 INTERCONNECT DUCT RETAINERS 17 F...

Page 4: ...ept as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitat...

Page 5: ...see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim sh...

Page 6: ...wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 11 The Limite...

Page 7: ...air work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 26 At no time will Blaze King be liable for any consequential damages which exceed the purch...

Page 8: ...plenum opening 30 5 8 L x 18 W Fire door opening 12 x 13 Firebox length 26 Width 14 Height 19 Capacity 4 cu ft Fuel length 24 Firebox design features 1 distributed draft system with preheated primary...

Page 9: ...Combustible material including firewood must be stored well away from the furnace outside of the distances specified for clearance to combustibles Never operate the furnace unless you are sure the smo...

Page 10: ...this booklet thoroughly and save it for future reference Carefully follow instructions for installation OPERATING INSTRUCTIONS LIGHTING THE FIRE NEVER START A FIRE UNLESS THE FURNACE IS CORRECTLY INST...

Page 11: ...ttle draft results in a sluggish fire and smoke backing up into the house when the furnace door is opened Too much draft over 06 in w c is unsafe and wastes fuel Use a Barometric damper when necessary...

Page 12: ...y cleaning to remove creosote buildup Remember the hotter the fire the less creosote A large smoldering fire causes more creosote than a small high heat fire We recommend that each day preferably in t...

Page 13: ...E IS BE ING OVERFIRED OPERATE THE ALTERNATE ELECTRIC GAS OR OIL FURNACE PERIODICALLY TO EN SURE THAT IT WILL OPERATE SATISFACTORILY WHEN NEEDED INSPECT VENT PIPES VENT PIPE JOINTS AND VENT PIPE SEALS...

Page 14: ...150 or equivalent White Rodgers 5D51 78 set at 220 or equivalent White Rodgers 5D51 78 set at 250 or equivalent Thermostat White Rodgers 1E78 or equivalent Poker Ash shovel Instruction book Insulation...

Page 15: ...OOD COUNTERFLOW INSTALLATION REQUIRES NOTE IN THIS CONFIGURATION SPECIAL CLEARANCES APPLY SEE CF6KIT INSTRUCTIONS DO NOT INSTALL IN THIS CONFIGURATION WITHOUT USING THE CF6KIT CF6 KIT OPTION ALTERNATE...

Page 16: ...on and maintenance of wood heating systems across Canada For your safety and satisfaction your system must be properly installed MINIMUM CLEARANCES TO COMBUSTIBLES See label copy addendum If the furna...

Page 17: ...e drop Static pressure at furnace minus static pressure at duct exit Record the pressure drop of the original system Addition of the add on furnace will add air flow resistance in the system After ins...

Page 18: ...chimney connector must be attached to either an approved masonry chimney or one of the listed factory built chimneys suitable for use with solid wood fuel All joints must be tight and fastened with sh...

Page 19: ...not necessarily assure proper flue draft Use a minimum total system height of 12 feet measured from the stove flue collar to the top of the chimney not including the chimney cap THERMOSTATS Stand alo...

Page 20: ...must not compress leads tightly against the surface DOOR AND LATCH INSTALLATION Install the firebox door on the frame hinges Install the door latch catch on to the frame mounting bracket as shown bel...

Page 21: ...l also THE OPERATION OF THE GAS FURNACE MUST BE VERIFIED FOR ACCEPTABLE OPERATION BEFORE AND AFTER INSTALLATION OF THE ADD ON BY A GAS FITTER WHO IS RECOGNIZED BY THE REGULATORY AUTHORITY DO NOT CONNE...

Page 22: ...S INDEPENDENT WOOD FURNACE When installed with a blower cabinet mounted on either side the MP80 becomes an INDE PENDENT wood only furnace The blower must have a minimum 900 cfm capacity In this config...

Page 23: ...ECTIONS WHEN USING ELECTRICAL FURNACE WITH W1 R C G CONNECTIONS You must connect the alternate furnace thermostat through the interlock limit switch to provide interlock lockout of the alternate furna...

Page 24: ...hen installing in a stand alone configura tion with a VB1000 blower Only 2 out of the three limit switches are used The middle limit is the Operating Limit and the right limit switch is the Safety Lim...

Page 25: ...10V Motor Adjustable from 900cfm to 1200 cfm 20Ga Steel Cabinet Construction High Quality Baked Enamel Finish Color matched to Valley Comfort Wood Furnaces Complete with 24 X 20 Air Filter Please chec...

Page 26: ...MP80 PUB Version 1 07 26...

Reviews: