59
Troubleshooting
RJ11 Error Codes
RJ11 Component IDs / Error Messages
Shown below are the component IDs and descriptions along with the possible error messages.
ID
Description
PRI-000
Com Port in panel, Example: PRI-000 Error Message
ENC-250 Com board in Position Encoder, Example: ENC-250 Error Message
GPS-251 Com Board in GPS tower box, Example: GPS-251 Error Message
IND-XXX
or
XXX-XXX
Individual, typically VRI-iS valve IDs. This can be an individual ID or a range of IDs followed by
the error message.
Example: Individual ID, IND-033 Error Message - or - Range of IDs, 111-121 Error Message
Error Messages
No Error
Invalid Request Length
Invalid Request Data
Invalid Request ID
Production Mode Not Activated
Serial Rx Buffer Full
CLTX Buffer Full
Cannot Commit When PLTX In Progress
No Answer From External Device Serial
Cannot Reach First Router
No Answer From Destination
Cannot Reach Destination
Answer From Destination Invalid
Figure 59-1
Viewing RJ11 Error Codes
ICON1, ICON5, ICON10 and ICONX
Control Panels
RJ11 Error Codes are communications failures that may
or may not shut the machine down. See Figures 59-2
and 59-3.
The RJ11 Errors screen shows up to 6 errors. When
the maximum number of 6 errors exist in the control
panel memory, any new error is added to the top of
the screen and the oldest record is discarded.
There is no notification that the RJ11 Error has occurred.
• To view the RJ11 Error Codes push
Menu
,
System
,
Diagnostics
,
Error
Codes
, and
RJ11
Comm
. A maximum of 6 errors are listed on the
screen, with the newest error at the top.
Clearing Error Codes
Clearing error codes will clear all RJ11 errors. See
Figures 59-2 and 59-3.
• To clear the RJ11 errors push
Clear Errors
. After the
errors are cleared the No Errors screen is displayed.
1
Figure 59-2 ICON5 and ICONX RJ11 Error Codes
1. Clear Errors
1
Figure 59-3 ICON1 and ICON10 RJ11 Error Codes
1. Clear Errors
Summary of Contents for VRI-iS
Page 2: ...2 This page was left blank intentionally...
Page 44: ...This page was left blank intentionally 44 Setup...
Page 50: ...50 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Field Install pn 9312421...
Page 51: ...51 Field Install and Wiring Diagrams VRI iS Power Supply Tower Box Wiring Schematic pn 0999334...
Page 52: ...52 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Field Install pn 9312419...
Page 53: ...53 Field Install and Wiring Diagrams VRI iS GPS Position Tower Box Wiring Schematic pn 0999346...
Page 82: ...82 Troubleshooting This page was left blank intentionally...