CONDENSING WATER
In the heating season, the extract air humidity
condenses to water. Water formation may be
abundant in new buildings, or if the ventilation is low,
compared to the humidity production of residents.
Condensed water must be able to get out of the
unit without obstruction. Check in conjunction with
maintenance, for example, during the autumn before
the heating season begins, that the condensing water
outlet on the bottom pool is not clogged and that
there is no leakage. You can check it by pouring a little
water into the pool. Clean, if necessary. Water must not
be allowed to enter the electrical system.
MOUNTING THE CONDENSING WATER
OUTLET
1. Push the main body of the condensing water
outlet from above through the hole at the bottom
plate of the ventilation device.
2. Push the tightening pin from below to the main
body.
3. Place the valve ball in the main body of the
condensing water outlet.
4. Attach the housing to the condensing water
outlet.
30
30
495 435
625
685
465
655
80
23 min.
30
133 min.
8
Ø 8
Ø 22
The length of the
adjusting screw is 37 mm
Thread bar M8x35
Shorter thread upward
MOUNTING
VALLOX 145 MV BASE
The base is optional. Adjust the base with adjusting legs to make
it straight. Remove the (4) rubber plugs at the bottom of the unit.
Place the unit on top of the base so that the bars of the base fit in
the holes at the bottom of the unit.
70 mm
NOTE
The standard SilentKlick condensing water outlet
installation requires 70mm of free space below
the ventilation unit.
MOUNTING