ELECTRIC

AL CONNECTIONS

EXTERNAL ELECTRICAL CONNECTION 

with Vallox Capto PTC EC control hood. 

EXTERNAL ELECTRICAL CONNECTION 

with the Vallox Simple Control control panel / Vallox PTXP MC, Vallox PTXPA MC 

cooker hood 

S + - LED

Simple Control

S

S

+

+

-

-

Control signal S

11.2 VDC / +

GND / -

Error relay / LED

LED

LED

Internal connection 

of the ventilation unit

S

+

-

LED

PTXP MC, PTXPA MC

7034500A  

ALARM

TACHO

GND

0-11V

PIEZO
+   -

DAMP
IN OUT

MODE
IN OUT

F ALARM

  RS 485
A  B GND

N

L

DAMPER

1    2    3

LIGHT

N    L

FAN

N    L

EC roof fan

Tacho

-

S

MC 

VENTILATION UNIT

Five terminal 

connector**

GND

S

GND

S

MC 

VENTILATION UNIT

Four terminal 

connector

MV 

VENTILATION UNIT

GND

AN/I

RM/I

RM/O

E/I

LED / E/O

PROGRAMMING 

CONNECTORS OF 

THE MOTHERBOARD

CONTACT DATA:

GUARD FUNCTION:

NORMAL SITUATION = OPEN

ACTIVATED = CLOSED

HOUSE AUTOMATION:

NORMAL SITUATION = OPEN

ERROR SITUATION 

(HOOD OR VENTILATION UNIT) = CLOSED

ACTIVATED GUARD FUNCTION = FLASHING

POSITION OF THE DAMPER:

DAMPER CLOSED = CONTACT OPEN

DAMPER OPEN = CONTACT CLOSED

* External error data is connected in the place 

  of the short circuit link of the mother board

** Disconnect the short circuit link between connectors 

    3 and 5 from the MC unit’s control panel connector

IN OUT

PE

EXTRA

DAMPER POSITION

CONTACT DATA

GUARD FUNCTION

CONTACT DATA

HOUSE AUTOMATION

CONTACT DATA

3 POTENTIAL  FREE CONTACT 

DATA 24VDC/5A

*NOTE!

Summary of Contents for 101 MC L

Page 1: ...Manual MANUAL Ventilation unit Document D4686 Valid from 02 10 2017 Updated 12 2 2018 Model Vallox 101 MC R Vallox 101 MC L Type 3740...

Page 2: ...uced sensory physical or mental capabilities or whose lack of knowledge and experience do not ensure safe operation of the unit Such persons can use the unit under supervision or by following the inst...

Page 3: ...the heat recovery cell is bypassed when the outdoor temperature is above 14 C The heat recovery will be turned on when the outdoor temperature falls below 12 C In the AUTO position the unit will oper...

Page 4: ...outdoor air is faulty Check the sensor and the wires replace as required 6 The supply air fan has stopped Check the wiring of the fan re place the fan as required 7 The extract air fan has stopped Ch...

Page 5: ...bient dust concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year HEAT RECOVERY CELL Check that the heat recovery cell D is clean roughly...

Page 6: ...rille the supply air fan must first be removed from the unit To remove the fan disconnect the quick connector H of the supply air fan T and or the extract air fan P cables Push the fan cables and the...

Page 7: ...ting season begins e g during autumn maintenance check that the condensing water outlets in the bottom pool are not clogged To check this pour some water into the pool Clean as required Water must at...

Page 8: ...rical connection 230V 50Hz 8 3A power plug Enclosure protection class IP34 Post heating radiator Power 1500 W Preheating radiator Additional heating radiator Fans Supply air Extract air 0 115 kW 0 9 A...

Page 9: ...1 23 30 35 41 44 51 53 56 20 20 20 20 20 21 22 24 26 29 LW dB LWA dB A 58 64 67 71 74 75 78 80 82 84 62 59 61 64 67 69 72 73 75 77 41 50 54 60 64 65 67 70 73 75 39 43 45 50 54 55 57 58 59 62 Sound pre...

Page 10: ...ink between connectors 3 and 5 from the female side of the control panel connector Post heating control PWM level adjustment 4 5 6 Protective earth to a separate block 7 8 9 1 Supply air fan 2 3 Extra...

Page 11: ...nnector GND S GND S MC VENTILATION UNIT Four terminal connector MV VENTILATION UNIT GND AN I RM I RM O E I LED E O PROGRAMMING CONNECTORS OF THE MOTHERBOARD CONTACT DATA GUARD FUNCTION NORMAL SITUATIO...

Page 12: ...RS 485 Common RH optional 946147 Nomak 2x2x0 5 0 5 0 10V LED G G0 Y1 Y2 DI1 A1 Y3 A2 Y4 U1 A B C S DI2 G0 Vallox Procontrol 949034 S LED S B term CONFIG Control signal S Cooker hood or boost switch 11...

Page 13: ...0 11 84 84 35 30 35 7 14 kpl 550 30 25 25 30 Wall mounting plate 283 164 6 604 Bottom edge of the wall mounting plate The top surface of the side panel of the unit can be installed against the finishe...

Page 14: ...ate Installing the ventilation unit to the ceiling mounting plate Remove the unit door Lift the unit and take the wires through the opening in the ceiling mounting plate Lift the ventilation unit agai...

Page 15: ...k water seal Installation height 53 mm installation space 73 mm outer diameter of the duct 12 mm Location of the condensing water outlets R and L models If the Vallox Silent Klick water seal does not...

Page 16: ...8225 6 HR cell 933260 7 Lower support for the HR cell 4102504 8 Upper support for HR cell 3467200 9 Filter frame extraction 978226 10 Filter G4 extract 978227 NO Part Product number 11 Bypass flap ass...

Reviews: