Ceiling mounting by using  

a ceiling mounting plate 

(optional)

The unit can be equipped with an optional ceiling 

mounting plate. The ceiling mounting plate must be 

fastened on rafter frames or other frame structure with 

M8 thread bars. The bars must be fastened so that they 

withstand the weight of the unit.
The ceiling mounting plate must be fastened horizontally 

to make sure that the unit is level. The ceiling mounting 

plate must be fastened so that there is a 10  mm gap 

between its rear edge and the finished wall. This way 

the ventilation unit will be installed as close to the wall as 

possible. The top edge of the white covering strip of the 

ceiling mounting plate can be installed against the finished 

ceiling. Alternatively, a concealed mounting method can 

be used, in which case the finished ceiling can be 30 mm 

or less from the top edge of the white covering strip.

The ceiling mounting plate is fastened to the M8 thread 

bars with the mounting supplies delivered with the 

mounting plate.  NOTE! The end of the thread bars must 

be 5mm or less below the fastening nut (more detailed 

instructions are provided with the ceiling mounting plate).

Installing the ventilation unit to the ceiling 

mounting plate

Remove the unit door. Lift the unit and take the wires 

through the opening in the ceiling mounting plate. Lift 

the ventilation unit against the ceiling mounting plate so 

that it locks in place. The unit has become locked on the 

ceiling mounting plate when the two operating levers on 

the mounting plate have been restored to the same level 

with the white covering strip of the ceiling mounting plate 

(more detailed instructions are provided with the ceiling 

mounting plate).

Ceiling mounting plate (optional)

The top edge of the white covering strip of the ceiling mounting plate can be installed against the finished ceiling. Alternatively, 

a concealed mounting method can be used, in which case the finished ceiling can be  30 mm or less from the top edge of the 

white covering strip.

The minimum distance from  

the finished rear wall is 10 mm

The recommended distance from  

the finished side wall is 10 mm

 598 

 10 

 10 

 598 

Finished wall

Finished wall

Concealed installation 

of the ceiling mounting plate 

on the ceiling, max. 30 mm.

 483 

 453 

 53 

 53 

Finished ceiling

Water seal Silent Klick

Installation 

space of t

he water seal 

73 mm

Installation 

space of 

the elbow 

47 mm

Concealed installation 

of the ceiling mounting plate 

on the ceiling, max. 30 mm

 483 

 453 

 38 

 38 

Finished ceiling

Elbow

 10 

Finished wall

Summary of Contents for 101 MC L

Page 1: ...Manual MANUAL Ventilation unit Document D4686 Valid from 02 10 2017 Updated 12 2 2018 Model Vallox 101 MC R Vallox 101 MC L Type 3740...

Page 2: ...uced sensory physical or mental capabilities or whose lack of knowledge and experience do not ensure safe operation of the unit Such persons can use the unit under supervision or by following the inst...

Page 3: ...the heat recovery cell is bypassed when the outdoor temperature is above 14 C The heat recovery will be turned on when the outdoor temperature falls below 12 C In the AUTO position the unit will oper...

Page 4: ...outdoor air is faulty Check the sensor and the wires replace as required 6 The supply air fan has stopped Check the wiring of the fan re place the fan as required 7 The extract air fan has stopped Ch...

Page 5: ...bient dust concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year HEAT RECOVERY CELL Check that the heat recovery cell D is clean roughly...

Page 6: ...rille the supply air fan must first be removed from the unit To remove the fan disconnect the quick connector H of the supply air fan T and or the extract air fan P cables Push the fan cables and the...

Page 7: ...ting season begins e g during autumn maintenance check that the condensing water outlets in the bottom pool are not clogged To check this pour some water into the pool Clean as required Water must at...

Page 8: ...rical connection 230V 50Hz 8 3A power plug Enclosure protection class IP34 Post heating radiator Power 1500 W Preheating radiator Additional heating radiator Fans Supply air Extract air 0 115 kW 0 9 A...

Page 9: ...1 23 30 35 41 44 51 53 56 20 20 20 20 20 21 22 24 26 29 LW dB LWA dB A 58 64 67 71 74 75 78 80 82 84 62 59 61 64 67 69 72 73 75 77 41 50 54 60 64 65 67 70 73 75 39 43 45 50 54 55 57 58 59 62 Sound pre...

Page 10: ...ink between connectors 3 and 5 from the female side of the control panel connector Post heating control PWM level adjustment 4 5 6 Protective earth to a separate block 7 8 9 1 Supply air fan 2 3 Extra...

Page 11: ...nnector GND S GND S MC VENTILATION UNIT Four terminal connector MV VENTILATION UNIT GND AN I RM I RM O E I LED E O PROGRAMMING CONNECTORS OF THE MOTHERBOARD CONTACT DATA GUARD FUNCTION NORMAL SITUATIO...

Page 12: ...RS 485 Common RH optional 946147 Nomak 2x2x0 5 0 5 0 10V LED G G0 Y1 Y2 DI1 A1 Y3 A2 Y4 U1 A B C S DI2 G0 Vallox Procontrol 949034 S LED S B term CONFIG Control signal S Cooker hood or boost switch 11...

Page 13: ...0 11 84 84 35 30 35 7 14 kpl 550 30 25 25 30 Wall mounting plate 283 164 6 604 Bottom edge of the wall mounting plate The top surface of the side panel of the unit can be installed against the finishe...

Page 14: ...ate Installing the ventilation unit to the ceiling mounting plate Remove the unit door Lift the unit and take the wires through the opening in the ceiling mounting plate Lift the ventilation unit agai...

Page 15: ...k water seal Installation height 53 mm installation space 73 mm outer diameter of the duct 12 mm Location of the condensing water outlets R and L models If the Vallox Silent Klick water seal does not...

Page 16: ...8225 6 HR cell 933260 7 Lower support for the HR cell 4102504 8 Upper support for HR cell 3467200 9 Filter frame extraction 978226 10 Filter G4 extract 978227 NO Part Product number 11 Bypass flap ass...

Reviews: