8
TECHNIC
AL SPECIFIC
ATIONS
Volume flow rate (dm3/s)
Volume flow rate (dm3/s)
Pressure loss in ducts. T
otal pressure (P
a)
Power
, W
Supply/extract air volumes
Power table
Combined input power of the fans (kW)
Airflow specified in the ventilation plan (m3/s)
SFP =
SFP rate (Specific Fan Power)
recommended value <1,8kW (m3/s)
T = supply air
P = extract air
Air flow measurement points
Measurement points after the outlet collar. The fan curves
indicate the total pressure accounted for by duct losses.
TECHNICAL SPECIFICATIONS
Product title
Vallox 101 MC R
Vallox 101 MC L
Product number
4102638
4102629
HVAC code
7912117
7912118
Air volumes Supply air
Extract air
90 dm³/s, 100 Pa
98 dm³/s, 100 Pa
Electrical connection
230V, 50Hz 8.3A power plug
Enclosure protection class
IP34
Post-heating radiator
Power, 1500 W
Preheating radiator
–
Additional heating radiator
–
Fans
Supply air
Extract air
0.115 kW, 0.9 A EC
0.115 kW, 0.9 A EC
Specific energy consumption (SEC)
in a cold climate
in a temperate climate
A+
B
Operating efficiencies
Annual efficiency
Supply air efficiency
Specific Fan Power (SFP)
70 % A
82 %
1,0 (38 dm
3
/s)
Filters
Supply air
Extract air
G4 + F7
G4
Heat recovery bypass
Automatic
Weight
50 kg
Extract air
Supply air
0
50
100
150
200
250
300
0,0
10,0
20,0
30,0
40,0
50,0
60,0
70,0
80,0
90,0
100,0
110,0
2,7 V
3,8 V
4,7 V
5,7 V
6,5 V
7,5 V
8,0 V
9,0 V
10,0 V
11,4 V
0
25
50
75
100
125
150
175
200
225
250
275
300
325
350
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110
2,7 V
6,5 V
7,5 V
T9,0 V
8,0 V
10,0 V
11,4 V
5,7 V
4,7 V
3,8 V
SFP 1,0
SFP 1,5
SFP 1,8